Specifications

3
OPERATION:
Read “IMPORTANT INFORMATION BEFORE USE” rst and verify all precautions are fullled before
operating.
Make sure the correct lamp is installed, read “SERVICE” on how to (re)place the lamp.
Although the DANCER250 cannot be dimmed, it may be switched on and off remotely using switch
packs or the full-on and full-off levels on dimmer packs. Disconnect the xture from AC power when
not in use.
The DANCER250 has an advanced control panel. To set the desired function please read the following
instructions carefully.
Power
Menu
DMX
Up Down
Enter
Sound
Control panel
DMX address setting:
1. Press
Menu
to access address code setting menu
Axxxx
2. Press
UP
or
DOWN
to set the
DMX
address code.
3. Press
ENTER
to save the update
DMX
address code.
Address code setting range
A001-A512
Motor Speed and Sound Sensitivity setting:
1. Press
Menu
to access the menu
StuP
2. Press
ENTER
to save the setting.
3. LCD display
Mot1
, press
ENTER
to access.
4. Press
UP
or
DOWN
to select motor speed, the range is 0-99.
5. Press
ENTER
to save the setting. Press
Menu
to exit.
6. In
Mot1
interface, press
UP
or
DOWN
to select
Mot2
and
SEnS
, the same setting as
SenS
is
sound sensitivity; 0 is closed, 99 max sound sensitivity.
StuP
Mot1
0-99
Gobo motor speed
Mot2
0-99
Gobo rotate motor speed
SenS
0-99
Sound sensitivity
Test program:
Press
Menu
to access the test program, select
TESt
and press
ENTER
to save the setting, the LCD
display ashes.
Press
Menu
to exit this scene.
Mode setting:
Press
Menu
to access the menu
ModE
and press
ENTER
button to save the setting.
Press
UP
or
DOWN
to select the mode of
Auto
or
Sond
or
dMH
.
Press
ENTER
to save the setting.
Press
Menu
to upgrade the menu.