Datasheet
306
GND 5
U: 0(2) ... 10 V
I: 0(4) ... 20 mA
26
25
24
© Fritz Kübler GmbH, subject to errors and changes. 10/2016
10V/30mA
+ SUPPLY
+ SIGNAL
- SIGNAL
- SUPPLY
GND 3
MP-INPUT1
MP-INPUT2
GND 2 (MP-INPUTS)
OUT 2
Limit 2
24VDC/30mA
OUT 1
Limit 1
10 ... 30V
AC
DC
1
2
3
4
5
6 7 89
10 11 12 13 14 15 16
17
+
for DC version
for AC version
100 ... 240V
±10 %
Strain-gauge controllers
Terminal assignment Rear side view
LED strain-gauge controllers Codix 566For strain-gauge inputs (AC+DC)
optional analog output
for DC version
Alarm outputs
Relays changeover contacts
Switching voltage max. 250 V AC / 125 V DC
min. 5 V AC / 5 V DC
Switching current max. 5 A AC / 5 A DC
min. 10 mA DC
Switching capacity max. 1250 VA / 150 W
Pull-in time approx. 10 ms
Analog output (optional - only for DC version)
Output ranges 0 (4) ... 20 mA / 0 (2) ... 10 V
Load current output ≤ 500 Ω
voltage output ≥ 2000 Ω
Resolution
15 bit
Update time 100 ms
(basic device measuring rate)
Temperature drift
≤ 100 ppm/K
Ambient
Accuracy ±0.1 % of the output range
high value
Output ripple ≤ 10 mV
Isolation voltage
500 V AC for 1 minute or
1 kV DC for 1 second