User manual
6
Model Operating
mode
Inputs
INP A INP B
6.134.012.8x0
6.134.012.8x1
6.134.012.8x3
6.135.012.8x0
6.135.012.8x1
6.135.012.8x3
Timer ––
00 ... 0,7 V DC
Timer ––
10 ... 260 V AC/DC
04 ... 30 V DC
10 ... 260 V AC/DC
00 ... 0,7 V DC
04 ... 30 V DC
10 ... 260 V AC/DC
DC operating modes:
Timer: INP A: no function
INP B: Timer-Enable-Input
Timer: INP A: Timer-Enable-Input AC/DC
INP B: reset input AC/DC
AC operating modes:
Table 1
Time range
99999h 59 m/
99999.99 h
9999 h 59 m 59 s/
9999999.9 s
10 ... 260 V AC/DC
NPN
PNP
AC/DC
NPN
PNP
AC/DC
AC/DC
AC/DC
Options: x = 5: no backlight
x = 6: with backlight
Main technical features:
Display: LCD, 8 decades, height of the figures 8 mm
Display range:
0 ... 99999999 with leading zeros
suppression.
Accuracy: < 100 ppm
Note: For one ON/OFF-cycle the counter can lose
max. one impulse of the selected time range
Overflow: In case of a display range overflow, the timer
starts again from 0, but without removing the
leading zeros and activating all decimal
points.
Keys: Electrical locking of the reset key
Housing: Panel mounting, 48 x 24 mm
according to DIN 43 700, RAL 7021
Panel cut-out:
22,2
+0,3
x 45
+0,6
mm
Mounting depth:
approximately 48 mm
Weight: approximately 50 g
Protection level:
IP65 on the front side
Overview
power lines.
– Cables and their insulation should be in accordance
w
ith the intended temperature, voltage and power
r
anges. The standards of the respective countries
apply.
D
C versions:
U
se shielded wires for the counting and control inputs
so as to obtain the maximum EMC resistance or con-
n
ect not used count inputs to ground (0 V).
AC versions:
U
se shielded wires for the counting and control inputs
so as to obtain the maximum EMC resistance.
1.9 Start-up
Is the device set and programmed correctly (function;
for counters, max. counting frequency)?
1.10 Failure possibilities and causes
Impossible to use the keys:
-
Key lock input activated
Counter does not count:
- Wrong or reversed wiring of the counting input
-
Setting of an input signal not matching the pulse gen-
e
rator
- Polarity (NPN/PNP) reversed
-
No ground connection between the pulse generator
and the counter
-
Signal levels do not reach the switching threshold of
the counter
If, despite all, your device still does not operate, contact
your local representative or call us directly for technical
support.
When sending your device back, please attach a short
description of the failure, of the programming and of the
connection diagram, in order to allow us to reproduce a
possibly existing defect and to repair your device as
quickly as possible.