Main technical features:
Display: LCD, 8 decades, height of the figures 8 mm
Display range:
0…99999999 with leading zeros
suppression.
Accuracy: < 100 ppm
Note: For one ON/OFF-cycle the counter can lose
max. one impulse of the selected time range
Overflow: In case of a display range overflow,
the timer
starts again from 0, but without removing
the leading zeros and activating all decimal
points.
Keys: Electrical locking of the reset key
Housing: Panel mounting, 48 x 24 mm
according to DIN 43 700, RAL 7021
Panel cut-out:
22.2
+0,3
x 45
+0,6
mm
Mounting depth:
approximately 48 mm
Weight: approximately 50 g
Protection level:
IP65 on the front side, device only
Connection:
Screw terminals, RM 5.00, 8 poles
Rated cross-section: max.: 1 x 1.5 mm
2
2 x 0.75 mm
2
AWG 26-14
EMC: Interference emissions EN 55011 Class B
Interference resistance EN 61000-6-2
Device safety (for the AC models):
Design to: EN 61010 Part 1
Protection Class: Protection Class 2 (front side)
Only the front side is classified as accessible
for the operator.
Application area: Pollution level 2
over-voltage Category II
Insulation: Front: double insulation,
Rear side: basic insulation, Signal inputs
and und sensor power supply:
SELV
• Signal levels do not reach the switching threshold of
the counter
If, despite all, your device still does not operate, contact
your local representative or call us directly for technical
support.
When sending your device back, please attach a short
description of the failure, of the programming and of the
connection diagram, in order to allow us to reproduce
a possibly existing defect and to repair your device as
quickly as possible.
Overview
Model Operating
mode
Time range Inputs
INP A INP B
6.134.012.8x0 Timer 99999h 59 m /
99999.99 h
– 0…0,7 V DC NPN
6.134.012.8x1 4…30 V DC PNP
6.134.012.8x1 10…260 V AC/DC AC/DC 10…260 V AC/DC AC/DC
6.135.012.8x0 Timer 9999 h 59 m 59 s /
9999999.9 s
– 0…0,7 V DC NPN
6.135.012.8x1 4…30 V DC PNP
6.135.012.8x3 10…260 V AC/DC AC/DC 10…260 V AC/DC AC/DC
Table 1
Options: x = 5: no backlight
x = 6: with backlight
DC operating modes:
Timer: INP A: no function
INP B: Timer-Enable-Input
AC operating modes:
Timer: INP A: Timer-Enable-Input AC/DC
INP B: reset input AC/DC
!