User's Manual
Table Of Contents
- 1. Introduction
- System Basic Features
- Technological Characteristics
- 4. Product Overview
- 5. Interface
- 6. Environmental Condition
- 7. Software Installation
- 8. Arbeit NMS software
- _
- 8.3.1 IDU Setting
- 8.3.2 ODU Setting
- 8.3.3 Alarm Setting
- 8.3.4 Cross Connecting
- 8.3.5 User I/O Setting
- 8.5.1 Background Setting
- 8.5.2 COM port Setting
- 8.5.3 Record Saving Time
- Local Loopback
- IF Loopback
- RF Loopback
- Remote Loopback
- PRBS Test
- 8.8.1 Alarm Record
- 8.8.2 Login Record
- 8.9.1 Help Window
- 8.9.2 About Arbeit
- 8.10.1 Network Monitor
- 8.10.2 Real-time Alarm
- _
- Appendix A: Technical Specifications
- Appendix B: LCD Alarm Description
- Appendix C: LCD Display&Function Table
- Appendix D: Frequency Spread Spectrum
- Appendix E: 5.8GHz ODU Block Diagram
- Appendix F: ODU Installation Guide
- Appendix G: RSL Calculation and Link Budget
- Appendix H: Arbeit Network Management System Tree
- Appendix I: Arbeit NMS Alarm
- Appendix J: ODU Troubleshooting Guide
- Appendix K: Antenna
5.8GHz PDH User’s Manual
54
8.7.1 Local Loopback
Local Loopback: Under the local loopback mode, it is easier to detect any malfunction at
the E1 interface. Testing equipment is required while detecting because on the execution
of this function, the testing signal cannot enter MOD, so it is not possible to use PRBS to
detect. This function setting is done through the NMS or the LCD display button.
In the System Test window, tick the Setting column for Tributary1. Press Accept Setting.
The IDU’s first E1 interface is now performing the local loopback test. There can be
multiple selection of the test. Press Clear All Test to stop all the settings performing the
test.
Local Loopback
8.7.2 IF Loopback