User's Manual
Table Of Contents
- 1. Introduction
- System Basic Features
- Technological Characteristics
- 4. Product Overview
- 5. Interface
- 6. Environmental Condition
- 7. Software Installation
- 8. Arbeit NMS software
- _
- 8.3.1 IDU Setting
- 8.3.2 ODU Setting
- 8.3.3 Alarm Setting
- 8.3.4 Cross Connecting
- 8.3.5 User I/O Setting
- 8.5.1 Background Setting
- 8.5.2 COM port Setting
- 8.5.3 Record Saving Time
- Local Loopback
- IF Loopback
- RF Loopback
- Remote Loopback
- PRBS Test
- 8.8.1 Alarm Record
- 8.8.2 Login Record
- 8.9.1 Help Window
- 8.9.2 About Arbeit
- 8.10.1 Network Monitor
- 8.10.2 Real-time Alarm
- _
- Appendix A: Technical Specifications
- Appendix B: LCD Alarm Description
- Appendix C: LCD Display&Function Table
- Appendix D: Frequency Spread Spectrum
- Appendix E: 5.8GHz ODU Block Diagram
- Appendix F: ODU Installation Guide
- Appendix G: RSL Calculation and Link Budget
- Appendix H: Arbeit Network Management System Tree
- Appendix I: Arbeit NMS Alarm
- Appendix J: ODU Troubleshooting Guide
- Appendix K: Antenna
5.8GHz PDH User’s Manual
46
Now let us introduce some other functions of the link route station setting:
Alarm Temperature Threshold:
Set the IDU&ODU secondary alarm temperature range. Enter the desired
parameters in the upper and lower IDU& ODU temperature alarm threshold dialog box.
When the temperature is higher than or lower than this threshold, the system alarm will
start beeping. The system has its own Operating Temperature threshold as well. As shown
in the Station Setup window, the IDU upper and lower Temperature threshold is +50 and
-5 respectively and the ODU are +60° and -30° respectively. The threshold can be set
between these two upper and lower thresholds. The upper threshold must not be too low
and the lower threshold must not be too high, if it is NOT so, the alarm will go off every now
and then even if all the setting are correct.
Number
Automatically generate a number from 1~255 for the convenience of calculating the
number of stations.