User's Manual

5.8GHz PDH User’s Manual
38
8.3.2 ODU Setting
Channel NoSet ODU RF transmitting and receiving power. The frequency channels used
are as follows:
4E1
1 5730.5 5737.5 5822.5 5829.5
2 5738.5 5745.5 5830.5 5837.5
3 5746.5 5753.5 5838.5 5845.5
UnitMHz
RF PowerSet ODU transmitting power, range 22~5dBm
SSPASwitch ON/OFF the ODU power amplifier (PA On/Off)
8.3.3 Alarm Setting
Under normal working condition, if the IDU goes into a critical state, the alarm will start
beeping. However, in some cases like if the administrator considers the Link ID
unimportant, s/he may tick “masked” and turn off all the alarm functions.
Link ID fault alarm – local station receives the wrong Link ID.
BER alarm – Bit error alarm
ODU Tx_POW alarm – ODU Output Power alarm
Tributary x loss alarm – IDU cannot find the tributary signal.