User's Manual

Textmenu Details
E1 Spread Spectrum Radios
8-19
8.2.12 Get Event Record
Figure 8-27 Get Event Record
Alarm record could record up to 1000 items which save in IDU memory. It is compatible with G.826 protocol
and record for functionality of system.
The major parameter of error lists below:
(1)Error Second(ES):The second with one or more errors.
(2)Severe Error Second(SES): The second which error occupied more than 30% of the second.
(3)Background Block Error(BBE):The second which deducts total seconds from error of SES.
(4)Unavailable Second(UAS): Continuous 10 SES is the start of UAS which 10 SES have been defined to be
part ot UAS.
The method is as follows:
STEP1: Proceed to HyperTerminal under windows, and from HyperTerminal can further reach login windows.
Then login by the account you wish.