User's Manual
E1 Spread Spectrum Radios
8-16
Temperature Alarm Threshold:
Figure 8-18: Temperature Alarm Threshold
Set the IDU & ODU alarm temperature range. Enter the desired parameters in the upper and lower IDU & ODU
temperature alarm threshold blanks. When the temperature is higher than or lower than this threshold, the system
alarm will start beeping. The system has its own Operating Temperature threshold as well. As shown in the Station
Setup window, the IDU upper and lower Temperature threshold is +50 and к -5 respectively and the ODU are к
+60° and к -30° respectively. The threshold can be set between these two upper and lower thresholds. The upper к
threshold must not be too low and the lower threshold must not be too high, if it is NOT so, the alarm will go off every
now and then even if all the other settings are correct.
No.
Number of Equipment already set up.
Change
For modifying any stations data, select that particular station and press Change to modify its content. Press Apply
after completing.
Add.
To add new stations.
Delete
To delete unwanted stations.
Terminal Station/Center Station