User's Manual
Table Of Contents
- K&A Wireless, LLC
- TABLE OF CONTENTS
- SAFETY NOTICES
- THIS DEVICE IS FOR PART 90 LICENSED OR EXPORT USE ONLY. Equi
- This product is intended for use in occupational/controlled
- This is NOT an intrinsically safe device. Do not take into
- DURING INSTALLATION, DO NOT OPERATE TRANSMITTER WITHOUT ANTE
- The transmitter is FCC approved under FCC ID: OPH-EV4600. C
- This product must be professionally installed. Additional i
- The radio and its antenna is required to be mounted and kept
- THIS DEVICE IS FOR PART 90 LICENSED OR EXPORT USE ONLY. Equi
- PARTS LIST
- PRODUCT DESCRIPTION
EV-TX-4500 Installation Manual… 10
_______________________________________________________________
2617 JUAN TABO NE SUITE A, ALBUQUERQUE, NM 87112 PHONE
888.536.5207 FAX 505.338.2382 sales@ka-wireless.com
EV-TX-4500 Installation Manual… 9
Additional documentation may be provided for specific
installations.
SPECIFICATIONS
RF Exposure
Specifications for the EV-TX-4600 SERIES
The FCC mandates that care be taken in the installation of
the antenna to insure that RF exposure limits are adhered
to.
RF
Operating
Frequencies
2458 MHz Channel 1
2474 MHz Channel 2
Frequency
Stability
+/- 0.005%
Output Power
10-900 mW factory set (+10 to 29.2
dBm)
Output
Impedance
50 ohms MMCX Female Connector
Modulation Direct Wideband FM
Modulation
Designators
2 Channel Transmitters 16M5F3F
Spurious and
Harmonics
less than 35 dBc
Video
Formats NTSC or PAL
Pre-Emphasis CCIR 405-1
Frequency
Response
<10 Hz to 5.5 MHz (+/-3dB)
Video Input
Levels and
Impedances
1 Volt Pk/Pk @75 ohms (Transmitter
Terminated)
1 Volt Pk/Pk @ 6K ohms (Customer
Terminated)
Distortion Less than 2% for all types
Modulation
Sense
Positive Input increases Frequency
(Negative Sense Available)
Modulation
Sensitivity
100 KHz per Volt
Distortion
less than 2% THD
For Occupational Applications, like firefighting, industrial
and law enforcement, etc., the integrated unit may be used
in handheld applications. In many handheld applications,
the 20cm requirement is restricted to the head and the
torso. In these cases, end user training must be provided
and disclosures regarding RF exposure must be provided.
The modular nature of the transmitter requires that the
antenna be mounted at least 20cm away from any persons
under normal operating conditions.
Any changes to the manufacturing process must be
approved in writing.
_______________________________________________________________
2617 JUAN TABO NE SUITE A, ALBUQUERQUE, NM 87112 PHONE
888.536.5207 FAX 505.338.2382 sales@ka-wireless.com