TK-C625.book Page 1 Thursday, March 31, 2005 4:20 PM DOME TYPE CAMERA TK-C625 INSTRUCTIONS For Customer Use: Enter below the Model No. and Serial No. which is located on the body. Retain this information for future reference. Model No. TK-C625 Serial No.
TK-C625.book 2 EN Page 2 Thursday, March 31, 2005 4:20 PM Safety Precautions FOR USA AND CANADA CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK. DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE.REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
TK-C625.book Page 3 Thursday, March 31, 2005 4:20 PM IMPORTANT SAFEGUARDS EN 3 These are general IMPORTANT SAFEGUARDS and certain items may not apply to all appliances. IMPORTANT SAFEGUARDS 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. Read all of these instructions. Save these instructions for later use. All warnings on the product and in the operating instructions should be adhered to. Unplug this appliance system from the wall outlet before cleaning.
TK-C625.book 4 EN Page 4 Thursday, March 31, 2005 4:20 PM Introduction Thank you for purchsing this product. (These instructions are for TK-C625U/TK-C625E) TK-C625U : For North American Market. TK-C625E : For European Market. “TK-C625” is used for common descriptions between both models in this manual. Before beginning to operate this unit, please read the instruction manual carefully in order to make sure that the best possible performance is obtained.
TK-C625.book Page 5 Thursday, March 31, 2005 4:20 PM Introduction (continued) EN 5 Operating Precautions 8 WARNING ●Install the unit on a strong and stable surface. This unit has been designed to revolve at high speed. Due to its weight (about 1.3 kg) and the vibrations it may be subjected to, the camera must be mounted to a sturdy and stable material.
TK-C625.book 6 EN Page 6 Thursday, March 31, 2005 4:20 PM Introduction (continued) Operating Precautions (continued) ●If a very bright object (such as a lamp) is being monitored, the picture may contain vertical lines (smear) above and below the bright object in the picture. This is a phenomenon normal to a solid-state image pickup device (CCD) and is not a malfunction. ●The electronic shutter speed of the camera has been set to 1/50 *(1/60) second at the factory.
TK-C625.book Page 7 Thursday, March 31, 2005 4:20 PM Introduction (continued) EN 7 Name and Function of Parts 8 Ceiling Mount (Terminal Side) I H G F E D A B C A Safety Wire F Locking Screw Hang this wire to the Fastening Hook for Safety Wire S. B [VIDEO OUT] Coaxial Cable Terminal Output terminal of a composite video signal (1 V(p-p)) with an output impedance of 75 K, to be connected to a switcher, etc. C [AC24V H INPUT] AC 24 V Input Terminal Connect to a AC 24 V power supply.
TK-C625.book 8 EN Page 8 Thursday, March 31, 2005 4:20 PM Introduction (continued) Name and Function of Parts (continued) 8 Camera 8 Ceiling Mount (Setting Switch Side) N S O J M P FRO NT K L J Q J Clamping Hole (x 4) Use these holes to attach the camera to the ceiling or ceiling recessed bracket (WB-S625: sold separately). K Camera Connection Terminal (Female) Connect this to the Camera Connection Terminal (Male) O on the camera.
TK-C625.book Page 9 Thursday, March 31, 2005 4:20 PM Connections & Installation EN 9 Multi-Drop Communication System A system that employs the RM-P2580 as the controller. The following figure shows a system that can accommodate up to eight cameras. (100 positions can be preset per camera.) Camera 1 Control signal cable TK-C625 Coaxial cable Observe the following points when connecting components together: ●Turn all the components off before proceeding.
TK-C625.book Page 10 Thursday, March 31, 2005 4:20 PM 10 EN Connections & Installation (continued) Multi-Drop Communication System (continued) A system that does not employ the RM-P2580 as the controller. MEMO ● Be sure to terminate the control signal cable at both ends. The cables (length of stub) connecting pieces of non-terminated equipment (cameras or controllers) must be as short as possible. If the length of stub is too long, control precision may suffer.
TK-C625.book Page 11 Thursday, March 31, 2005 4:20 PM Connections & Installation (continued) EN 11 Point-to-Point Communication System The following illustration shows a system in which a remote control unit (or a similar piece of equipment) controls a single camera.
TK-C625.book Page 12 Thursday, March 31, 2005 4:20 PM 12 EN Connections & Installation (continued) Point-to-Point Communication System (continued) Use twisted-pair cables for the connections. ●Duplex When the camera is controlled using the full duplex protocol, set the Switch 5 of the Setting switch to ON. Camera RX + Controller TX + RX - TX - TX + RX + TX - RX - Four wires must be connected.
TK-C625.book Page 13 Thursday, March 31, 2005 4:20 PM Connections & Installation (continued) EN 13 Switch Settings Set the switches on the Ceiling Mount before installing the camera. Settings vary according to configuration of the system used. 8 Setting switches AMachine ID Setting SwitchB (A pg.
TK-C625.book Page 14 Thursday, March 31, 2005 4:20 PM 14 EN Connections & Installation (continued) Switch Settings (continued) 8 Machine ID Setting Switch When controlling the system using a multi-drop remote control unit such as RM-P2580, for instance, assign a number (machine ID) for identification to each of the connected cameras. Assign a machine ID according to the video input number of RM-P2580.
TK-C625.book Page 15 Thursday, March 31, 2005 4:20 PM Connections & Installation (continued) EN 15 8 Machine ID Set the Machine ID using a combination of numbers between 1 to 8. (This is set to OFF in the factory settings.
TK-C625.book Page 16 Thursday, March 31, 2005 4:20 PM 16 EN Connections & Installation (continued) Cable Connections CAUTIONS ●Ensure to attach the cover for the ceiling mount. Installation is not possible without attaching the cover. ●The cover prevents penetration of foreign objects into the ceiling mount. Penetration of foreign objects may cause a malfunction or, in the worst scenario, cause smoking or fire.
TK-C625.book Page 17 Thursday, March 31, 2005 4:20 PM Connections & Installation (continued) EN 17 Connection of Alarm Input / Output Terminals Connection of Coaxial Cables Connect the alarm input/output terminals to external devices such as sensors and buzzers. Connecting an RG-59 coaxial cable. Strip the tip of the coaxial cable according to the diagram below. A Follow the diagram below to loosen and remove the screws on the two edges of the terminal block.
TK-C625.book Page 18 Thursday, March 31, 2005 4:20 PM 18 EN Connections & Installation (continued) Cable Connections (continued) Connection of Control Signal Cables Connect this to the remote control unit (RM-P2580). The maximum permissible length of the control signal cable during connection with RM-P2580 is 1200m. (RM-P2580 allows connection of a set of cables to multiple cameras. In this case, the total length of the cables shall not exceed 1200m.) Connection of Power Connect to an AC 24 V Supply.
TK-C625.book Page 19 Thursday, March 31, 2005 4:20 PM Connections & Installation (continued) EN 19 Installing the Ceiling Mount 2 Fasten the ceiling mount to the ceiling CAUTIONS ● Attachment of a recessed cover in the ceiling (recess bracket) may be mandatory in certain regions. If this is so, ensure that the recessed cover (recess bracket) is securely attached before installing the camera.
TK-C625.book Page 20 Thursday, March 31, 2005 4:20 PM 20 EN Connections & Installation (continued) Installing the Camera 1 Attach the Safety Wire 4 Turn the camera Follow the diagram to pull out the Safety Wire from the ceiling mount, followed by hanging it to the Fastening Hook for Safety Wire on the camera. Make sure that the camera is not tilted, followed by pushing the camera against the ceiling mount and turning it in the clockwise direction until it stops.
TK-C625.book Page 21 Thursday, March 31, 2005 4:20 PM Setting Up the Camera Using RM-P2580 EN 21 Setup Procedure MENU button Power switch (Rear panel) SET button POWER lamp In systems using an RM-P2580 remote control unit, the menus for use during camera setup can be displayed on the remote control unit. (Please refer to the Instructions for RM-P2580.
TK-C625.book Page 22 Thursday, March 31, 2005 4:20 PM 22 EN Setting Up the Camera Using RM-P2580 (continued) Menu Screen Configuration Normal screen Press the MENU button for 1 second SETUP POSITION SETUP. . CAMERA. . CONTROL UNIT. . A pg. 21 A pg. 24 MENU CAM.FUNCTION1.. CAM.FUNCTION2.. CAM.TITLE/ALARM.. CAM.ALC/VIDEO.. AUTO PAN/PATROL/TRACE.. POS.FUNCTION SET.. FACTORY SETTINGS..
TK-C625.book Page 23 Thursday, March 31, 2005 4:20 PM Setting Up the Camera Using RM-P2580 (continued) A pg. 31 1 EN A pg. 34 A pg. 31 PRIVATE MASK MODE MASK No. MASK EDIT .. MASK DELETE .. CAMERA TITLE EDIT 0123456789ABCDEFGHIJKLMNO PQRSTUVWXYZabcdefghijklmno p q r s t u v w x y z ÄÖÜÊÎÔÛÇÑäëïöü âêîôûáéíóúàèìòùçñß¡¿ .
TK-C625.book Page 24 Thursday, March 31, 2005 4:20 PM 24 EN Setting Up the Camera Using RM-P2580 (continued) CAMERA FUNCTION 1 Screen Function/Set Value Initial Value This adjusts the vertical synchronization to those of other cameras when a selector switch for the synchronizing system on the Ceilling Mount is at LL. (50 Hz *(60Hz) power region only.
TK-C625.book Page 25 Thursday, March 31, 2005 4:20 PM Setting Up the Camera Using RM-P2580 (continued) TILT LIMIT 25 Function/Set Value Initial Value When in the B&W mode, this camera is sensitive to both visible and near-IR lights. As such, images may become out of focus upon switching from the Color to B&W mode, depending on the type of light source used. Set to ON in this case to adjust focus automatically. OFF : Disabled. ON : Enabled.
TK-C625.book Page 26 Thursday, March 31, 2005 4:20 PM 26 EN Setting Up the Camera Using RM-P2580 (continued) CAMERA TITLE/ALARM Screen Item Function/Set Value CAM. TITLE EDIT.. Use this to specify the title that is always displayed at the bottom left of the screen. Specify up to a maximum of 16 characters. ACAMERA TITLE SetupB (A pg. 34) AREA DISPLAY Use this to perform area setting. AAREA DISPLAY Setup (TITLE)B (A pg. 35) AAREA DISPLAY Setup (DIRECTION)B (A pg. 36) OFF Not displayed.
TK-C625.book Page 27 Thursday, March 31, 2005 4:20 PM Setting Up the Camera Using RM-P2580 (continued) EN 27 CAMERA ALC/VIDEO Screen This screen enables automatic adjustment according to the brightness. Setting can be performed for the camera video signals, such as color level and contour enhancement. Item SHUTTER Function/Set Value Sets the speed of the electronic shutter.
TK-C625.book Page 28 Thursday, March 31, 2005 4:20 PM 28 EN Setting Up the Camera Using RM-P2580 (continued) CAMERA ALC/VIDEO Screen (continued) Item Function/Set Value Initial Value COLOUR LEVEL (TK-C625E) COLOR LEVEL (TK-C625U) Adjusts the color level of video signals. To decrease…………… Set a smaller value. To increase……………. Set a larger value. [Set values: -5 to NORMAL to 5] NORMAL ENHANCE LEVEL Sets the contour enhancement which controls the sharpness on the monitor screen.
TK-C625.book Page 29 Thursday, March 31, 2005 4:20 PM Setting Up the Camera Using RM-P2580 (continued) Item AUTO PAN TRACE/ VIDEO.. IRIS MODE AVERAGE : PEAK EN 29 Initial Value Function/Set Value For setting video images during Auto Pan and Auto Trace. ^ For setting the method of lens iris adjustment. AUTO : Adjusts iris automatically to the default state. AUTO+ : Adjusts iris automatically to a level brighter than the default state.
TK-C625.book Page 30 Thursday, March 31, 2005 4:20 PM 30 EN Setting Up the Camera Using RM-P2580 (continued) POS. FUNCTION SET Screen (continued) Item AVERAGE : PEAK Initial Value Function/Set Value For setting the method of exposure detection according to the ratio between the average and peak values. ●Larger AVERAGE Value : Use this setting when areas other than those highlighted are dark and unclear.
TK-C625.book Page 31 Thursday, March 31, 2005 4:20 PM Setting Up the Camera Using RM-P2580 (continued) EN 31 PRIVATE MASK Setup MENU button SET button PAN lever CAMERA button REMOTE CONTROL UNIT RM-P2580 SETUP MENU CAMERA POWER POSITION ALARM SET AUTO F-1 F-2 1 Select the camera.
TK-C625.book Page 32 Thursday, March 31, 2005 4:20 PM 32 EN Setting Up the Camera Using RM-P2580 (continued) MANUAL PAN LIMIT Setup This section describes procedures for setting the Panning (horizontal) range during manual operation.
TK-C625.book Page 33 Thursday, March 31, 2005 4:20 PM Setting Up the Camera Using RM-P2580 (continued) EN 33 MANUAL PAN LIMIT Setup (continued) Right Limit Invalid Range V alid R an g e Left Limit 8 Basic operation of Manual Pan Limit ●Panning operation will only be allowed within the valid range upon setting the Manual Pan Limit.
TK-C625.book Page 34 Thursday, March 31, 2005 4:20 PM 34 EN Setting Up the Camera Using RM-P2580 (continued) CAMERA TITLE Setup MENU button SET button PAN lever CAMERA button REMOTE CONTROL UNIT RM-P2580 SETUP MENU POWER CAMERA POSITION ALARM SET AUTO F-1 F-2 F-3 KEY LOCK Use the CAMERA TITLE screen to set the title of each camera. Titles can be up to 16 characters in length and are displayed at the bottom left of the picture. 1 Select the camera.
TK-C625.book Page 35 Thursday, March 31, 2005 4:20 PM Setting Up the Camera Using RM-P2580 (continued) EN 35 AREA DISPLAY Setup (TITLE) This section describes procedures to display area titles on the screen, when the 360° panning (horizontal) range is divided into 16 areas and when the camera is manually rotated. Title for each area can be specified up to 16 characters. (Turning ON/OFF Area Title display AAREA DISPLAYB (A pg. 26)) 1 Select a camera.
TK-C625.book Page 36 Thursday, March 31, 2005 4:20 PM 36 EN Setting Up the Camera Using RM-P2580 (continued) AREA DISPLAY Setup (DIRECTION) Upon setting N (North), which is the standard axis, the 360° panning range will be equally divided into 8 areas. Perform manual panning of the camera and each area will be displayed as N, NE, E, SE, S, SW, W, NW. SW SE East West E CAMERA buttonNNumeric key (Camera Number)NENTER button ●Video images of the selected camera will be output.
TK-C625.book Page 37 Thursday, March 31, 2005 4:20 PM Setting Up the Camera Using RM-P2580 (continued) EN 37 ALARM TITLE Setup MENU button SET button PAN lever CAMERA button REMOTE CONTROL UNIT RM-P2580 SETUP MENU POWER CAMERA AUTO F-1 F-2 1 Select the camera. (A RM-P2580 AINSTRUCTIONSB) CAMERA buttonNNumeric key(Camera Number)NENTER button ●The picture of the selected camera is output.
TK-C625.book Page 38 Thursday, March 31, 2005 4:20 PM 38 EN Setting Up the Camera Using RM-P2580 (continued) AUTO PAN Setup This section describes procedures for setting the Auto Pan function, which enables gradual horizontal rotation of the camera. There are 3 Auto Pan modes, namely movement between 2 points, rightward rotation and leftward rotation. Gradual Rotation Ima end ge of pos ition f ge o Ima sition t po star 1 Select camera.
TK-C625.book Page 39 Thursday, March 31, 2005 4:20 PM Setting Up the Camera Using RM-P2580 (continued) EN 39 AUTO PATROL Setup High speed POSI N ITIO POS 1 TION 2 High speed High speed POS ITIO N 4 TION POSI 3 High speed Use the AUTO PATROL screen to set the configuration of the Auto Patrol function, which moves the camera between several positions at a high speed. Patrol positions 1-100 can be set in each of three modes (MODES 1 to 3).
TK-C625.book Page 40 Thursday, March 31, 2005 4:20 PM 40 EN Setting Up the Camera Using RM-P2580 (continued) AUTO TRACE Setup MENU button AUTO PAN button SET button PAN lever CAMERA button REMOTE CONTROL UNIT RM-P2580 SETUP MENU POWER CAMERA POSITION ALARM SET AUTO F-1 F-2 F-3 KEY LOCK Use the AUTO TRACE screen to set the Auto Trace function, which stores and reproduces the actions of a manual camera operation (up to 30 seconds). 1 Select the camera.
TK-C625.book Page 41 Thursday, March 31, 2005 4:20 PM Setting Up the Camera Using RM-P2580 (continued) EN 41 POSITION TITLE Setup Use the POSITION TITLE screen to set the title of each camera position. Each camera position can be given a title of up to 16 characters. POSITION button MENU button SET button PAN lever CAMERA button 1 Select the camera.
TK-C625.book Page 42 Thursday, March 31, 2005 4:20 PM 42 EN Other Troubleshooting Symptom Cause (Information) Remedy Picture is not displayed. Is there a problem in the power cable(s) connecting the camera to the power supply unit? (If the power cable(s) are too long or of an inadequate size, the correct voltage may not be supplied due to an increase in cable resistance.) Use cable(s) with low cable resistance and of the correct cable length.
TK-C625.book Page 43 Thursday, March 31, 2005 4:20 PM Other (continued) EN 43 Specifications 8 Camera Image pickup device:1/4 type, interline transfer CCD TK-C625E: 752 (H) x 582 (V) pixels TK-C625U: 768 (H) x 494 (V) pixels Sync system : Internal, Line Lock Video output : VBS 1V (p-p) 75 K Scanning frequencies : TK-C625E: 15.625 (H), 50 Hz (V) TK-C625U: 15.734 (H), 59.
TK-C625.book Page 1 Thursday, March 31, 2005 4:20 PM TK-C625 DOME TYPE CAMERA is a Registered Trademark owned by Victor Company of Japan, Ltd. is a Registered Trademark in Japan, the U.S.A., the U.K. and many other countries.