TK-C215VP4_JP.book Page 1 Wednesday, September 20, 2006 6:02 PM DOME CAMERA TK-C215VP4 TK-C215VP12 INSTALLATION PRECAUTIONS To installation contractor : Be sure to read the followings beforehand for proper installation. Pass the manual to user after reading. To user : Please be sure to keep together with the instruction manual after reading.
TK-C215VP4_JP.book Page 2 Wednesday, September 20, 2006 Safety Precautions Precautions regarding fall prevention warning Mounting to a firm place. When mounting this unit to the ceiling or wall, mount it to a secure location where it can support the mass of this unit. When mounting to an insecure location, make sure to carry out reinforcement of the ceiling or wall before installation. The camera unit may fall if the mounting screw or piping is not properly tightened.
TK-C215VP4_JP.book Page 3 Wednesday, September 20, 2006 Precautions for proper installation Precautions regarding water-proof and dust-proof 6:02 PM 䡵 Inserting the silica gel supplied Take out the silica gel from the aluminum package, insert it into the silica gel insertion space of the camera unit and fasten using the lug plate. 䡵 Fill the hole with sealing material Fill the piping hole as well as the 2 mounting holes mounted with screws using a sealing material.
TK-C215VP4_JP.book Page 4 Wednesday, September 20, 2006 Precautions for proper installation (continued) Precautions regarding water-proof and dust-proof (continued) 䡵 Precautions when mounting the dome cover 6:02 PM 䡵 Binding the sealing tape. (When mounting the camera using the pipe) Bind at least 2 layers of the sealing tape to the joint of the pipe (point where the thread of the piping hole coincides with the screw hole of the pipe).
TK-C215VP4_JP.book Page 1 Wednesday, September 20, 2006 5:48 PM DOME CAMERA TK-C215VP4 INSTRUCTIONS For Customer Use: Enter below the Serial No. which is located on the body. Retain this information for future reference. Model No. Serial No.
TK-C215VP4_JP.book Page 2 Wednesday, September 20, 2006 5:48 PM Introduction Safety Precautions Information for Users on Disposal of Old Equipment [European Union] Attention: This symbol is only valid in the European Union. This symbol indicates that the electrical and electronic equipment should not be disposed as general household waste at its end-of-life.
TK-C215VP4_JP.book Page 3 Wednesday, September 20, 2006 INFORMATION FOR USA 䡵 INFORMATION This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
TK-C215VP4_JP.book Page 4 Wednesday, September 20, 2006 5:48 PM Introduction Safety Precautions (continued) 䢇 The unit is to be powered by a DC 12 V or an AC 24 V power supply. 䢇 The unit is to be powered by a UL Listed DC 12 V or an AC 24 V power supply. (For U type) 䢇 The AC 24 V and 12 V DC power supply shall conform to the following: Class 2 only (For USA), Isolated power supply only (For Europe). 䢇 This installation should be made by a qualified service person and should conform to all local codes.
TK-C215VP4_JP.book Page 5 Wednesday, September 20, 2006 5:48 PM These are general IMPORTANT SAFEGUARDS and certain items may not apply to all appliances. IMPORTANT SAFEGUARDS 1. 2. 3. 4. Read all of these instructions. Save these instructions for later use. All warnings on the product and in the operating instructions should be adhered to. Unplug this appliance system from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning. 5.
TK-C215VP4_JP.book Page 6 Wednesday, September 20, 2006 5:48 PM Introduction Thank you for purchasing this product. (These instructions are for: TK-C215VP4U/TKC215VP4E.) Before beginning to operate this unit, please read the instruction manual carefully in order to make sure that the best possible performance is obtained.
TK-C215VP4_JP.book Page 7 Wednesday, September 20, 2006 5:48 PM Table of Contents Introduction Safety Precautions .................................... 2 Characteristics .......................................... 6 Table of Contents ...................................... 7 Precautions for proper use of this product .................................. 8 Name of Parts ........................................... 9 Camera ................................................. 9 Camera (Interior) ...................
TK-C215VP4_JP.book Page 8 Wednesday, September 20, 2006 5:48 PM Introduction Precautions for proper use of this product Storage and Location of Use 䢇 Do not install this unit at the following locations. ● Places that are exposed to vapor or oil, such as kitchens.
TK-C215VP4_JP.book Page 9 Wednesday, September 20, 2006 5:48 PM Name of Parts Camera A B C F D E A Mounting hole ⳯ 2 C Mounting Screw for Fall Prevention Wire Use these when mounting the camera to the ceiling, wall or electrical box. (A Pg. 17)(A Pg. 25) Use this screw when mounting the fall prevention wire to this unit. (Fall prevention wire is not supplied with this product.
TK-C215VP4_JP.book Page 10 Wednesday, September 20, 2006 5:48 PM Introduction Name of Parts (continued) Camera (continued) K J I G H G Base J Protection Cover Mount the base to the ceiling, wall or electrical box before mounting the camera. (A Pg. 17)(A Pg. 25) Upon connecting the coaxial cable, protect it by insulating the metal part of the BNC connector K from the ceiling structure. H Fastening Screw for Dome Cover K Video signal output connector (BNC) (A Pg.
TK-C215VP4_JP.book Page 11 Wednesday, September 20, 2006 5:48 PM Camera (Interior) L Lens (A next page) X W M V N O P U Q R S T L Rotation Knob U Tilt Fastening Screw Rotate the lens unit to adjust the inclination of the image. (A Pg. 22) Upon adjusting the angle of view, tighten the screw to ensure that camera’s angle of view does not go out of alignment when it is used at a location with strong vibration. (A Pg. 22) M Rotation Center Mark (A Pg.
TK-C215VP4_JP.book Page 12 Wednesday, September 20, 2006 5:48 PM Introduction Setting the Lens and Switches Set the video setting switches on the camera unit before mounting it. To set the switches, use a fine-tipped screwdriver. A F G RESET/ [SPOT] B R B LL PHASE C D E O N 2 1 2 3 4 5 6 7 8 4 WHT. BAL. L IRIS LEVEL H FOCUS ADJUST Function Selection Switch Settings Chart (Characters in bold indicate factory settings) OFF 1 2 3 4 5 6 7 8 AGC SELECT SYNC WHT.BAL.
TK-C215VP4_JP.book Page 13 Wednesday, September 20, 2006 3. [SYNC] Synchronization system selection switch. This switch sets the synchronizing system for the camera. INT: This is set for internal synchronization LL (Line Lock): The camera’s vertical synchronization is locked to the AC 24 V 60 Hz or 50 Hz power line frequency.
TK-C215VP4_JP.book Page 14 Wednesday, September 20, 2006 5:48 PM Installation and Connection System Example ● Turn off the power of devices to be used before connecting the cables. ● Read through the “Instruction Manual” of the devices to be used carefully before connecting.
TK-C215VP4_JP.book Page 15 Wednesday, September 20, 2006 About Connection Cables The maximum connection distance varies with the type of cable used. Please refer carefully to the table for each cable during connection. * Be sure to turn off the power of devices before connecting cables. To video Signal Cable To DC 12 V or AC 24 V Power Supply 5:48 PM DC 12 V or AC 24 V power supply cable Connect the DC 12 V or the AC 24 V power supply to the DC 12 V/AC 24 V terminals on the terminal board.
TK-C215VP4_JP.book Page 16 Wednesday, September 20, 2006 5:48 PM Installation and Connection Procedures from Connection to Setting Follow the procedures below to connect/set this unit. Turn off the power of devices to be used before connecting the cables. 䢇 Before touching the camera unit, make sure to touch the metal surface of the [MONITOR] terminal to discharge any static electricity from your body. Static electricity may cause the camera to malfunction.
TK-C215VP4_JP.book Page 17 Wednesday, September 20, 2006 Setting the switches 5:48 PM Mounting the base Remove the dome cover, followed by setting the video image switches. 1. Removing the dome cover Remove the dome cover by unfastening the 3 fastening screws using the wrench supplied. Memo: Remove the camera unit from the base and mount the base to the ceiling or wall. When mounting to a wall, follow the procedures by replacing areas indicated as [ceiling] by [wall] accordingly.
TK-C215VP4_JP.book Page 18 Wednesday, September 20, 2006 5:48 PM Installation and Connection Mounting the base (continued) 2. Mounting the fall prevention wire to the 3 Base 8 mm base (fall prevention wire is not supplied) Remove the fastening screw for the fall prevention wire and mount the fall prevention wire. 3. Mounting the fall prevention wire to a firm place To prevent the camera from falling, mount the base to a firm place using the fall prevention wire. 4.
TK-C215VP4_JP.book Page 19 Wednesday, September 20, 2006 5:48 PM Cable Connection 1. Connecting the coaxial cable (A Pg. 15) Lower the protection cover and connect the connectors. Upon connecting, cover the connectors using the protection cover. 2 2. Connecting the AC 24 V/DC 12 V power Solder or Caulk supply wires Note: Insulating Tape ● To mount a heater (sold separately) to this unit, make sure to connect it to an AC 24 V supply during use. 1 Protection Cover Coaxial Cable 3.
TK-C215VP4_JP.book Page 20 Wednesday, September 20, 2006 5:48 PM Installation and Connection Mounting the camera unit Fill the piping hole and mounting hole with a sealing material, mount the camera unit to the base, and insert the silica gel. 1. Fill the hole with sealing material Fill the piping hole as well as the 2 mounting holes mounted with screws using a sealing material. 2. Mounting the camera unit to the base Press the 2 lugs until a “click” sound is heard.
TK-C215VP4_JP.book Page 21 Wednesday, September 20, 2006 5:48 PM 4. Inserting the silica gel supplied Take out the silica gel from the aluminum package, insert it into the silica gel insertion space of the camera unit and fasten using the lug plate. Silica Gel Insertion Space Silica Gel Lug Plate Memo: ● During reconnection or re-installation after repair or maintenance, make sure to replace the silica gel with a new one. ● Consult your nearby JVC’s dealer on the replacement procedures.
TK-C215VP4_JP.book Page 22 Wednesday, September 20, 2006 5:48 PM Installation and Connection Adjusting the video image Panning: ±175 ⬚ Upon mounting the camera, adjust the images while checking the actual image. Mounting the test monitor Connect the [MONITOR] terminal of this unit to the test monitor to adjust the camera’s shooting direction, angle of view and focus. Memo: Rotation: ±175 ⬚ ● Before setting, ensure to turn on the power of the system.
TK-C215VP4_JP.book Page 23 Wednesday, September 20, 2006 Adjusting the angle of view, focus and brightness Upon determining the imaging direction, adjust the angle of view, focus and brightness accordingly. Note: ● When adjusting the focus, make sure to cover the dome cover over the lens. The dome cover of this unit is thick. Therefore, if the focus is not adjusted with the dome cover covered, this may cause the lens to go out of focus when the dome cover is mounted.
TK-C215VP4_JP.book Page 24 Wednesday, September 20, 2006 5:48 PM Installation and Connection Mounting the inner dome Mounting the dome cover After setting is complete, mount the inner dome to the camera. 1. Cleaning the dome cover 1. Mounting the inner dome Before mounting, remove any dust or dirt from the dome cover. Mount the inner dome to the 3 lugs. Memo: ● Dirt that is not removed from the cover before mounting may appear on the camera’s image.
TK-C215VP4_JP.book Page 25 Wednesday, September 20, 2006 Note: ● Make sure that the dome cover is firmly fastened. Otherwise, the humidity level may rise, which may result in fogging and even falling of the cover. ● Ensure that the fall prevention wire of the dome cover is not caught in the space between the dome cover and base. Failing to do so may cause the dust-proof and waterproof features to malfunction. 5:48 PM Mounting the camera using the electrical box Mounting the base to the electrical box.
TK-C215VP4_JP.book Page 26 Wednesday, September 20, 2006 5:48 PM Installation and Connection Mounting the camera using the pipe Sealing Tape 4 12 mm(15/32 inch) and below Use the piping hole to mount the camera. 7 Mounting the camera using the piping hole at the bottom surface of the base Fall Prevention Wire 5 1. Setting the switches (A Pg. 17) 2. Removing the camera unit from the base. 3 (A Pg. 17 , step 1) 3. Mount the fall prevention wire to the base (A Pg. 18) 4.
TK-C215VP4_JP.book Page 27 Wednesday, September 20, 2006 Mounting the camera using the piping hole at the side surface of the base If the camera cannot be mounted directly to the ceiling, mount it to the pipe using the piping hole at the side surface of the base. 1. Setting the switches (A Pg. 17) 2. Dismantle the camera unit from the base 5:48 PM 5. Mounting the removed plug for the piping hole to the piping hole at the bottom surface of the base 6.
TK-C215VP4_JP.book Page 28 Wednesday, September 20, 2006 Installation and Connection White-spot correction As a general characteristic unique to CCDs, white-spots may appear on the screen with age. In order to reduce this phenomenon, this unit is equipped with a white-spot correction feature. Switch on the camera power supply and wait for at least 30 minutes. RESET/ [SPOT] B R [SPOT] button LL PHASE 1 2 3 4 5 6 7 8 O N 2 4 WHT. BAL. Function selection switch 8 1. Remove the dome cover. 2.
TK-C215VP4_JP.book Page 29 Wednesday, September 20, 2006 5:48 PM Others Specifications White balance: : ATW/Manual (Switchable) Color temperature range 2,300 K to 10,000 K 䡵 Camera Signal system: U type : Based on NTSC standard E type : Based on PAL standard Scanning frequencies U type : 15.734 kHz (Horizontal), 59.94 Hz (Vertical) E type : 15.
TK-C215VP4_JP.book Page 30 Wednesday, September 20, 2006 5:48 PM Others 䡵 Dimensional Outline Drawing Specifications (continued) [Unit: mm (inch)] 䡵 General 121(4 3/4) Power supply : AC 24 V H 50 Hz/60 Hz DC 12 V 113(4 1/2) 1 Power consumption U type : 4.2 W : 23 W (When using KAZH215) E type : 340 mA : 1 A(When using KA-ZH215) 1 1 1 1 1 1 1 E type: Instructions ................................................ Installation Precautions ............................. Silica Gel ...................