TK-C210FW/TK-C215V4/ TK-C215V12 DOME CAMERA DOME CAMERA TK-C210FW TK-C215V4 TK-C215V12 INSTRUCTIONS For Customer Use: Enter below the Serial No. which is located on the body. Retain this information for future reference. Model No. TK-C210FW/TK-C215V4/TK-C215V12 Printed in Thailand © 2005 Victor Company of Japan, Limited LST0308-001B-H Serial No.
Introduction I Safety Precautions INFORMATION FOR USA Information for Users on Disposal of Old Equipment [European Union] This symbol indicates that the electrical and electronic equipment should not be disposed as general household waste at its end-of-life. Instead, the product should be handed over to the applicable collection point for the recycling of electrical and electronic equipment for proper treatment, recovery and recycling in accordance with your national legislation.
Introduction (continued) These are general IMPORTANT SAFEGUARDS and certain items may not apply to all appliances. IMPORTANT SAFEGUARDS 1. 2. 3. 4. Read all of these instructions. Save these instructions for later use. All warnings on the product and in the operating instructions should be adhered to. Unplug this appliance system from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning. 5.
Introduction (continued) Contents Introduction Safety Precautions .......................................... 2 Characteristics ................................................ 5 Contents.......................................................... 6 Operating Precautions .................................... 7 Name of Parts ................................................. 8 Camera........................................................ 8 Camera (Interior) .........................................
Introduction (continued) Camera (Interior) Name of Parts The picture below shows the camera when the dome cover and outer case are removed. Procedures for removal. (A pg. 18 AEmbedding the camera to the ceilingB, Step 3. to Step 4.) Camera I H G A B U TK-C215V12 only F B A Mounting hole (elliptical) x 4 Use these when mounting the camera to the electrical box. (A pg. 22) NOTE: When installing the camera onto the electric box, install it using the supplied adaptor ring.
Introduction (continued) A [RESET/SPOT] RESET/SPOT button Setting the Lens and Switches (TK-C215V4) Set the video setting switches on the camera unit before mounting it. To set the switches, use a fine-tipped screwdriver. A RESET/ [SPOT] B R B LL PHASE C 1 2 3 4 5 6 7 8 D E O N 2 4 WHT. BAL. L IRIS LEVEL H FOCUS ADJUST F When this button is pressed, the value of the white balance or phase adjusted manually is reset to the default value. ● When the 2 [SELECT] switch is set to WHT.BAL.
Introduction (continued) B [ZOOM/FOCUS, MEMORY] zoom, focus Setting the Lens and Switches (TK-C215V12) RESET/[SPOT] R B LL PHASE IRIS L TELE ZOOM/FOCUS NEAR ALARM POSITION 2 FAR WIDE 4 POSITION SELECT 1 2 3 4 5 6 7 8 A B C D LEVEL [MEMORY] WHT.BAL. H Set the video setting switches on the camera unit before mounting it. To set the switches, use a fine-tipped screwdriver.
Installation and connection Setting the Lens and Switches (TK-C210FW) Set the video setting switches on the camera unit before mounting it. To set the switches, use a fine-tipped screwdriver. About Connection Cables The maximum connection distance varies with the type of cable used. Please refer carefully to the table for each cable during connection. * Be sure to turn off the power of devices before connecting cables. To video Signal Cable BLC To DC 12 V or AC 24 V Power Supply OFF ON A 1. 2.
Installation and connection (continued) System diagram Mounting the Camera to the Ceiling TK-C215V4 Video signal Getting Started Power CAUTION: Video signal Power TK-C215V12 Video signal Power Select a method for mounting the camera according to the intended purpose. AEmbedding the camera to the ceilingB (A pg. 18) ● When mounting the camera to the ceiling, ensure to wear safety glasses to protect the eye from any falling object.
Installation and connection (continued) 4. Remove the outer case. 䡵 Connecting 䡵 Mounting 1. Attach the fall prevention wire to the 1. Align j with the shooting direction when Embedding the camera to the ceiling (This method does not require an outer case.) A Loosen the outer case fastening screw with a screwdriver B To remove, turn the camera unit in the anticlockwise direction * Make use of a ceiling material with a thickness between 9.5 mm to 22 mm. 5.
Installation and connection (continued) Installation and connection (continued) 䡵 Mounting 6. Set the switches for video images. Mounting the Camera to the Ceiling (continued) (TK-C215V4 A pg. 10) (TK-C215V12 A pg. 12) (TK-C210FW A pg. 14) When mounting the camera directly to the ceiling or on the wall When mounting to a wall, replace areas indicated as “ceiling” in the procedures by “wall”. 6. 4. A 1. Align the position mark of the fastened outer case with that of the camera unit.
Installation and connection (continued) Mounting the Camera to the Ceiling (continued) When mounting the camera to the electrical box NOTE: Before mounting the camera to electrical boxes, please consult your nearby JVC authorized dealer for details on the type of electrical box for which mounting is possible. Adjusting Image Mount by allowing the cable to exit from the side When mounting the camera to the ceiling or a wall, it is possible to guide the cable from the side without opening any holes.
Adjusting Image (continued) 䡵 TK-C215V4 TK-C215V4 (A pg. 24) F TK-C215V12 (A pg. 25) CAUTION: Focus ring W T *TK-C215V4 is used in the above illustration Adjusting field angle Loosen the fastening screw for the zoom adjustment ring and move the ring to the left/right to adjust the image. Adjusting focus ● When setting images on TK-C215V12, ensure that the lens is covered using the dome cover. This camera is equipped with a high magnification lens.
Adjusting Image (continued) 1. Remove the dome cover. Adjusting Images (continued) Mounting the Dome Cover After setting is complete, mount the dome cover. RESET/[SPOT] B LL PHASE R L H LEVEL [MEMORY] WHT.BAL. NEAR ALARM POSITION TELE ZOOM/FOCUS FAR WIDE 2 POSITION SELECT 4 1.,5. 1 2 3 4 5 6 7 8 Position mark 1. As a general characteristic unique to CCDs, white-spots may appear on the screen with age.
Others Specifications 䡵 Camera Signal system: U type : Based on NTSC standard E type : Based on PAL standard Scanning frequencies U type : 15.734 kHz (Horizontal), 59.94 Hz (Vertical) E type : 15.
Others (continued) 䡵 External Dimensions [Unit: mm (inches)] When embedded 46 (1-13/16) 44 (1-3/4) 20 (13/16) φ (7 22 /8) 4.5 (3/16) 6CDNG JQNG - (3 55 ) SR -1/8 (2 9 φ8 ) 1/2 φ116 (4-9/16) 83.5 (3-5/16) 4-φ4.5 (3/16) 71 (2-13/16) 6 (1/4) 2 (1/12) When cover is attached φ145 (5-3/4) S (2 R55 -1 /8) 120 (4-3/4) φ120 (4-3/4) φ145 (5-3/4) * Specifications and appearance of this unit and related products are subject to change for product improvement without prior notice.