Camera Accessories User Manual
Ver1.1
45
KY-F550 Random Trigger System
Trigger signal  
Charges accumu-
(a)
lated in the CCD
Sync non-reset mode  (a)  (a)  (b)  (b)
Image output signal
SI output signal
(b)
(b)
(a)
For verifying the image of an object detected.
If the trigger signal for the object detected is input, charges will be output 
following the next SYNC signal while simultaneously, the SI signal will be 
output as well, hence allowing the images to be stored in the memory.
The method of SYNC non-reset mode allows camera timing to be output 
irrespective of trigger input signal.