User manual

Table Of Contents
TC/UB Menu
Menu screen for setting time code and user’s bit.
This item cannot be selected in the Media mode,
or during recording.
TC Mode
For configuring the TC mode settings.
0
NTP:
Activates
NTP
synchronization of the time code
and superimposing of TC information
(metadata) on the streaming data. This option is
selectable when the [TC GEN] selection switch
is set to F-RUN. When “NTP” is selected, the unit
will operate in the F-RUN mode regardless of the
position of the [TC GEN] selection switch.
0
GPS u v:
Uses the
GPS clock (UTC). The unit will operate
in the F-RUN mode if GPS clock data cannot be
acquired.
0
SW Set:
Follows the settings of the [TC GEN] switch.
0
Clock:
This is
set to “Clock” when the [TC GEN] switch
is set to “F-RUN”.
[Setting Values: NTP, GPS, RSW Set, Clock]u
v
[Setting
Values: NTP, RSW Set, Clock]w x
Memo :
0
When the
[TC GEN] selection switch is set to “R-
RUN” or “REGEN”, or during “Interval Rec”,
“Frame Rec” and “High-Speed”, the setting is
fixed at “SW Set”.
0
[TC/UB] cannot be changed during live
streaming when “NTP” is selected.
9
Time Zone
For configuring the time zone.
0
Local Time:
Time code with time zone corrected for time
information obtained from NTP
0
UTC:
Time code without time zone correction
[Setting Values: Local Time, RUTC]
Memo :
0
This item
can be configured when [TC Mode] is
set to “NTP”.
9
Streaming Format
For configuring the time code system.
[Setting Values: LTC, RVITC]
Memo :
0
This item
can be configured when [TC Mode] is
set to “NTP”.
0
This is fixed at “VITC” when [Live Streaming
] B
[Optional Adapter] is set to “Enable”.
TC Preset
For setting the time code (hour, minute, second,
frame).
Display :
Drop setting 02:02:25.20
: Non Drop setting 02:02:25:20
(A P76 [Setting Time Code Generator] )
Memo :
0
When the [TC GEN] switch is set to “REGEN”,
“<Regen>” is displayed and preset is disabled.
0
When [TC Mode] is set to “Clock”, “<Clock>” is
displayed and preset is disabled.
126
TC/UB Menu
Menu Display and Detailed Settings