Operation Manual

1414
Transparent Adjust the transparency of the level meter display against the image. Off, Background, All
Peak Hold Activates/deactivates the peak hold function of the level meter. Off, On
Lissajous Setting Lissajous setting
<Lissajous display example>
H Axis Channel(X) Select an EMBEDDED AUDIO CH to display on the horizontal axis of the Lissajous screen. 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,
12, 13, 14, 15, 16
V Axis Channel(Y) Select the EMBEDDED AUDIO CH to display on the vertical axis of the Lissajous screen. 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,
12, 13, 14, 15, 16
Position Select a position to display the screen. Lower Right, Lower Left,
Upper Left, Upper Right
Transparent Set the background of the screen to translucent. Off, On
Gain Specify the Lissajous gain. 0dB, +6dB, +12dB
Audio Delay Audio delay setting
Delay Delay EMBEDDED AUDIO of SDI input. 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
*
1
Operates as SDI-1 during Dual Link input.
*
2
Memorized for each input.
Scope Setting*
1
Configure the settings for the wave form monitor, vector scope and histogram.
Item To do Setting value
Gain*
2
Adjust the input gain level. –10 to +10
Size*
3
Set the window size. Normal, Large
Position Select the window position. Lower Right, Lower Left
Upper Left, Upper Right
Transparent Activates/deactivates the function to make the window translucent. Off, On
Off
On
:
:
Normal
Translucent
Auto Off Set the function to turn off the window automatically 15 minutes after displayed. Off, On
Histogram Display Select the signal component for the histogram display. Y, R, G, B, RGB
Wave Display Select a wave form to be displayed for the wave form monitor. Y, Pb, Pr (HD signal)
Y, Cb, Cr (SD signal)
R, G, B (RGB signal)
Wave Filter Turn on/off the lowpass filter to put over the input wave form data. Flat (No filter)
Low pass
Wave Over Level Marking Turn on/off the function to change the wave form color of signals over the value specified in
“Wave Over Level”. (+ below)
Off, On
Wave Over Level Adjust the lower limit for the over level. 70 – 109
<Example of the histogram display> <Example of the wave form monitor> <Example of the vector scope>
<dark brightness
light >
Pixels
Image signals
Start End
Red White
Y
Mg
R
B
100% level
75% level
Cy
G
Yl
The start and the end of the gradient
correspond to 0% and 100% of the signal.
Ex.: When the luminance signal is Y, “Wave Over
Level Marking” is set to “On” and “Wave Over
Level” is set to “80”
• Thewaveformcolorofsignalsoverthevalue
specified in “Wave Over Level” turns red.
• Thedisplaydiffersdependingontheinput
signal or the “Wave Display” setting.
Ex.: When the color bar is displayed
*
1
The vector scope is not displayed when the input signals are RGB.
*
2
Unavailable for the histogram.
*
3
The size of the histogram can only be “Normal.”
Y
X
Menu Configuration (cont.)
DT-V24G2_EN.indb 14 2016/07/27 16:37:14