Operation Manual
Function
Trigger
For configuring 12 V output to an external screen equipped with a trigger function.
Setting Description
Off No output.
On (Power) Outputs control signals (12 V) from the trigger terminal when the power is turned
on.
0
After the power is turned off, output stops when the unit shifts to the Standby
mode after cooling is complete.
0
You
can
also output signals in the Standby mode by pressing the [OK] button.
On (Anamo) Outputs control signals when the “Anamorphic” setting is switched from “Off” to “A”
or “B”.
Off Timer
For setting the timing to power off the unit automatically (“1 Hour”, “2 Hours”, “3 Hours”, or “4 Hours”) when it is not
operated for a period of time.
High Altitude Mode
Set to “On” when using the projector at a location of low atmospheric pressure (higher than 900 m above sea level).
ECO Mode
Setting Description
On Minimizes power consumption in the Standby mode.
0
If there
is no signal transmission or operation for 30 minutes while an image is
projected, the power is turned off automatically.
Off Set to “Off” if RS-232C / LAN communication is performed or the HDMI link function
is used in the Standby mode.
Communication Terminal
For setting the external control terminal to be used to “RS-232C” or “LAN”.
Network
Setting Description
DHCP Client On Obtains the IP address automatically from the DHCP server inside the connected
network.
Off For configuring the network settings manually.
IP Address For configuring the IP address.
Subnet Mask For configuring the subnet mask.
Default Gateway For configuring the default gateway.
MAC Address Displays the MAC address of the unit.
Set Applies the network settings.
62