MODEL: AIRCO9000
Content User Instructions Precautions .............................................................................................................................................................. 1 Important Safety Tips .............................................................................................................................................. 3 Special Remindings ...............................................................................................................................
User Instructions The meaning of the icons used in this manual is as follows: For you and your family’s health and safety, such actions are prohibited. For you and your family’s health and safety, please be sure to do the following items Precautions Use the machine in rooms, and place it in a dry environment, and do not use it outdoors. This machine is intended for household. Do not use for others Do not pile items around the machine, to avoid obstructing the machine to exchange air.
Do not operate the machine with wet hands or in damp environment. Wipe the machine with a soft cloth, and do not use wax, thinner or irritating detergents. For your health, do not drink the condensed water the machine discharged. Clean the air filter regularly. Once every two weeks is recommended. If you don’ t use the machine for a long time, unplug the power cord. Non-professionals do not disassemble or repair the machine without authorization .
Important Safety Tips Do not use damaged power cord or power plug. Do not plug the power cord into loose outlets. Do not damage or use damaged power cord or power cord with unknown type. Before using, ensure the voltage used to meet the requirements. Do not attempt to modify or extend the power cord. Use grounding receptacle when operating the machine. Do not handle the plug with wet hands. This operation may cause an electric shock.
Do not control the machine on and off state by plugging and unplugging power cord. Turn off the unplugging. machine before Do not share an outlet with multiple high electrical appliances. Keep the machine away from heat sources and avoid direct sunlight. If the machine sends a strong noise, odor or smoke, switch it off, disconnect the plug and contact the service centre. Do not place heavy objects on the power cord to avoid it being crushed and causing electric shock.
Do not put your fingers or hard objects into the air outlet. Do not allow water to enter the machineÿ s electrical parts. If there is water inside the machine, turn it off and disconnect its plug immediately, and then contact qualified service personnel for servicing. If it needs wiping, cleaning, moving or replacement of machine parts, turn it off and unplug it. When a gas leak occurs, please open windows to ensure air circulation and then run the machine.
Special Remindings Place the air conditioner on flat ground and keep it placed vertically to ensure the normal operation of its compressor. The space between the air conditioner and its surrounding objects shall be ensured to be 50cm at least, and its air inlet or outlet shall be kept unobstructed. Do not use the machine near gasoline or other flammable liquids.
Product Presentation Name of Main Components 1. Handle 3 2. Air inlet (left) 4 1 3. Control panel 2 4. Air guide bar 5 5. Truckle 6. Remote controller 8 6 7. Air inlet(right) 9 8. Air outlet 7 10 9. Outfall 10. Inlet grille 11. Exhaust pipe assembly 12.
Single refrigeration Cold and heat producing
Product Usage Placement and Installation Placement ·Place the machine on flat floor near a window; ·To maintain a good air circulation and obtain an optimum machine performance, it shall leave a 50cm space around; Installation Exhaust pipe assembly Exhaust joint Exhaust pipe Exhaust flat-mouth Window seal plate assembly Bolt 9 Window sealing plate 1 Window sealing plate 2
Step 1: (1) Measure window size: (2) Adjust the length of the window sealing plate, making it to fit the size of the window; (3) After the length of window sealing plate is determined, fix it length dimension with screws. Step 2: Install the fixed window sealing plate on the window. Step 3: Screw the exhaust pipe assembly (exhaust joint end) into the rear panel exhaust port (counter clockwise).
Step 4: Place the exhaust pipe assembly (exhaust flat port) into the window sealing plate assembly and fix it with screws.
Incorrect installation • The smoothness of exhaust pipe is very important. Incorrect installation will affect the operation of air conditioners; • In installation, avoid the exhaust pipe bending substantially; • Ensure the air flow smoothly inside the pipe. Warning: The exhaust pipe length is specially designed for this model, do not arbitrarily replace or extend it, or it will lead to failure easily. Note: The maximum developed length of exhaust pipe is 1500mm. shorten its length as far as possible in use.
Warning: 1. If there is battery leakage, do not the battery; 2. Chemicals inside the battery may cause burns or other health hazards; if their liquid flows to the skin or clothing, rinse with water immediately; if eating it accidentally, gargle with water immediately, and then go to a hospital and see a doctor for further examination.
Operation Method Refrigeration mode ·After being powered and turned on, its refrigeration mode by default or pressing mode button to select refrigeration mode, and the refrigeration indicator light is on. ·Press the up or down button to adjust the set temperature (17°C--30°C) . ·Press the wind speed button to select high, medium or low wind speed. Fan only mode • Press the mode button or via the remote controller to select fan only mode, . and fan only indicator light is on.
Time mode ·In standby mode, press time button to set time start. Press the up-and-down button to the time of start (0~24 hours), and time indicator light is on. ·In startup mode, press time button to set time switch-off. Press the up-and-down button to the time of switch-off (0~24 hours), and time indicator light is on. Cleaning and Maintenance Drainage Method The product has an automatic water evaporation system. The circulation of condensed water cools the condenser.
Filter screen It’s recommended to cleaning the filter screen once every two weeks, if the indoor air quality is poor, cleaning frequency shall be raised. Since the filter becomes clogged with dust, the machine cooling effect will be reduced. Specific cleaning steps are as follows: 1. Remove the intake grille and then filter screen in the direction shown in the following picture below; 2.
Seasonal Maintenance If the machine will be not in use for a long time, its maintenance follows the steps below: 1. Pull out the drainage cap to drain off water; 2. Keep the machine working 2 hours in the air distribution mode until its inside becomes dry; 3. Turn it off and pull the plug out; 4. Clean its filter screen and reinstall back; 5. Remove its exhaust pipe and accessories, and keep them safely; 6. Remove the batteries from remote controller; 7.
Common Failure and their Diagnostics Intelligent Failure Detection Detecting code E1 E2 Multi-function testing Coil temperature sensor failure Indoor temperature sensor failure E4 Anti-freeze protection: when the coil temperature is below 0°C, the whole machine will stop. When the coil temperature rose to 8°C or more, the protection will leave, and it will restore to its original work state.
34 0m m 830mm Machine Dimensions 443mm 19