OIL CAPACITY Being just a teaspoon low affects the ultimate vacuum. CHANGING OIL To reach deep vacuum, Eliminator pumps need clean, moisture-free oil throughout evacuation. Care should be taken to avoid contact on skin and clothing when changing oil. Used oil should be disposed of in a leakproof corrosive-resistant container. Model DV-3E 24.5 oz. Models DV-4E & DV-6E 22.5 oz. Slowly add oil until oil level rises even with arrows on front of cover. Replace oil fill plug.
REPAIR PARTS 18 17 20 13 21 14 16 18 15 11 12 19 8 New Cover Will Fit Old Black Eliminators 9 10 Repair parts can be ordered from your local JB Wholesaler. When ordering please provide the following information: OLD ELIMINATOR IMPORTANT: OIL LEVEL MUST BE ABOVE HALF WAY IN SIGHT GLASS OIL LEVEL –Model number NEW ELIMINATOR –Serial number –Part number and description IMPORTANT: OIL LEVEL MUST BE ABOVE HALF WAY IN SIGHT GLASS LEVEL OIL No Longer available REF. NO. PART NO.
TROUBLESHOOTING CHART Symptom Possible Cause(s) Corrective Action 1. Power cord not plugged in securely. 1. Plug power cord in securely. 2. Motor switch not on. 2. Turn motor switch to ON position. 3. Pump temp. below 30°F. 3. Warm up pump to 30°F & turn motor switch on. 4. Inconsistent line voltage. 4. Line voltage must be within 10% of 115 volt. 1. Contaminated oil. 1. Change oil. 2. Oil level too low. 2. Add oil. 3. Air leak in system being evacuated. 3. Locate & repair leaks. 4.