Owner's Manual

Page 2 For technical questions, please call 1-888-866-5797. Item 57335
Specifications
Input
Voltage
12 VDC Nominal
(11-15 VDC)
Wire Gauge 2/0 AWG (up to 3 ft.)
Internal Fuses 35 A x 10
Input Fuse Rating 350 A
Current 289 A (rated)
Output
Continuous 3000W
Surge 6000W
Receptacles
4 AC outlets,
1 USB port
Waveform Modified Sine Wave
Voltage Range 120VAC
Frequency 60 ±2Hz
Current 26.09 A
Ground Wire Gauge 8 AWG
No Load Current
(Switch on)
<1.0A (at 12.5VDC)
Maximum efficiency 90%
Full load efficiency >80%
Over voltage Shutdown 15.75 ±0.75 V
Low voltage alarm 10.5 ±0.5 V
Low voltage shutdown 10 ±0.5 V
Thermal Shutdown 192 ±18 °F
Note: Battery charge level, wire length and
other factors will effect performance.
WARNING SYMBOLS AND DEFINITIONS
This is the safety alert symbol. It is used to alert you to potential personal injury hazards.
Obey all safety messages that follow this symbol to avoid possible injury or death.
Indicates a hazardous situation which, if not avoided,
will result in death or serious injury.
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
Indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury.
Addresses practices not related to personal injury.