JUN-X8 DC Battery Charger Manual

X8
Mini Balance Charger/Discharger/DC Power
- 14 -
As shown in the above picture, the program of LiPo, LiIo, LiFe, LiHV and LTO battery has: Charge, Storage, Discharge,
Cycle and Balance Only.
LiPo/LiIo/LiFe/LiHV/LTO Battery Charge Setup
Select Program→Charge to enter Charge setup interface.
Note: 1. When the value of charge cells voltage exceeds the recommended value (LiPo 4.2V, LiIo 4.1V, LiFe 3.6V,
LTO 2.85V),
the charger will display a warning and alarm. As long as the user changes the default value, the battery types
and cells voltage value on the main charging interface will be displayed alternately.
2. For the setting process for all program in this manual, tick Show to display the setting program on MEMORY
SETUP (shown in the following picture), and vice versa; the built-in program is ticked by default.
LiPo/LiIo/LiFe/LiHV/LTO Battery Not Balance Charge Setup
When switch to Not Balance on Chg Mode, Only Chg End Current is available for charging end condition, and
” behind Chg Mod and Chg End Current are inactive.
Note: The charger first charges with constant current (CC) according to the user setting, then turns to constant voltage
(CV) when the charging voltage reaches the peak point. In the CV phase the current gradually falls, and the
charger will terminate charging when the current falls below the percentage of the configured charge current.
For example: the default value of Chg Current is 2A, and the default value of Chg End Current is 10%
Chg End Current=2A*10%=0.2A
Therefore it stops charging when the charging current reduces to 0.2A.
Chg Current: 0.05A-30A; default: 2A
Chg Mode: Slow Balance, Normal Balance (default),
Fast Balance, User Balance, Not Balance
Chg End Current: 1%-50%; default: 10%
Chg Cell Volt: 3.85V/Cell-4.35V/Cell;
Default: 4.2V/Cell
Cells: Auto (default), 1-8S