Installation Guide

IMPORTANT SAFETY INSTRUCTIONS
1. Read all of these instructions before installing fixture.
2. Keep these instructions in a safe place for future reference
3. Only qualified electricians in accordance with local codes
should perform all installations.
4. WARNING: FOR HARD WIRE INSTALLATION (NM & BX)
MAKE SURE ELECTRICAL POWER SUPPLY FOR INSTALLA-
TION CIRCUIT IS SHUT DOWN AT ELECTRICAL SERVICE
PANEL BEFORE STARTING INSTALLATION. DO NOT
RE-ENERGIZE CIRCUIT UNTIL INSTALLATION IS FULLY
COMPLETED.
5. Fixture is designed to be electrically grounded for hard wire
(NM & BX) installations. WARNING: TO PREVENT SHOCK
CLOSELY FOLLOW GROUNDING DIRECTIONS.
TWO WAYS TO ELECTRICALLY FEED FIXTURE
Electrical power can be brought to the fixture using two different
techniques:
Non-Metallic Cable (NM) using ROMEX PLATE
(provided and mounted on fixtures).
Armored Cable (BX) using optional CONDUIT PLATE
and die-cast aluminum electrical connector
(provided loose).
Connections can also be made using fixture knockouts
and connector supplied loose.
Wiring module accessory ULH-DWM (sold separately)
can be used for forward mount applications if necessary to
allow for remote supply wiring.
WIRING CONNECTIONS - Non-Metallic Cable (NM)
1. Loosen screw on ROMEX PLATE and remove.
(Figure 1)
2. Push NM supply cable through rectangular wire grip
in plate so outer jacket of cable projects about 3/4˝
through plate. (Figure 2)
3. Inside fixture are three wires with PUSH-IN WIRE
CONNECTOR fitted to each end. Carefully pull these
out of fixture. Do not pull with excessive force.
(Figure 3)
4. Using strip length guides on PUSH-IN WIRE
CONNECTOR make sure lengths of exposed wire on
supply cable are correct.
5. Insert each of the three wires from the NM supply
cable into each of the three PUSH-IN WIRE
CONNECTORS with respective color wires. Black to
black, white to white, and green (or bare copper
wire) to green. Make sure that feed wires are
securely gripped by the PUSH-IN WIRE CONNECTOR
and that with the exception of a bare ground wire,
none of the supply wires show exposed wire where
they enter the PUSH-IN WIRE CONNECTOR.
6. Neatly push wires and PUSH-IN WIRE CONNECTORS
into opening in back of the fixture.
7. Properly engage ROMEX PLATE in back of fixture
and tighten screw. Do not over tighten screw. Make
sure that lock washer is installed under head of
screw for proper grounding.
WIRING CONNECTIONS - Armored Cable (BX)
1. Loosen screw on ROMEX PLATE. Remove plate and
discard. (Figure 1)
2. Mount die-cast aluminum electrical connector to the
flat side of the CONDUIT PLATE. Securely tighten
nut. (Figure 4)
3. Push BX cable into connector. Make sure BX cable
has a properly installed plastic insulating bushing
(not provided). Tighten clamp screws securely
making sure that BX cable remains fully seated in
connector during tightening.
4. Perform steps 3-7 (under Wiring Connections —
Non-Metallic Cable (NM) ).
NOTE: In some BX installations there may not be a
separate grounding wire provided. Grounding is
achieved through the spiral wound metal jacket of
the BX cable.
NOTE: The die-cast aluminum connector can also be
used with NM cable if desired.
NOTE: 2 die-cast connectors can be used for loop
feed supply wiring if desired. (For 2nd die-cast
connector, order accessory ULH-CONN.)
SAVE THESE INSTRUCTIONS
NON-METALLIC
CABLE (NM)
ROMEX PLATE
© 2007 JUNO Lighting Inc. pg 1 of 2
For use with 120V, 60Hz electrical power supply only. WARNING: TO PREVENT OVERHEATING AND ELECTRICAL SHOCK DO
NOT INSTALL IN SMALL ENCLOSED SPACES. TO PREVENT ELECTRICAL SHOCK DO NOT INSTALL IN WET ENVIRONMENTS.
INSTALLATION INSTRUCTIONS
PRO-SERIES FLUORESCENT UNDERCABINET LIGHT
Juno UPF Series T5 Fluorescent Luminaires
MOUNTING SCREW
PUSH-IN WIRE CONNECTOR
ARMORED CABLE
(BX)
CONDUIT PLATE
& CONNECTOR
(2 ports provided for
loop-feed supply wiring if desired)
ROMEX PLATE
Figure 1
Figure 2
Figure 3
Figure 4