Installation Guide

R29 Floating Feed
Makes electrical connection at standard Junction Box. Use at any point of
Trac run under Junction Box.
1. Make sure power is OFF.
2. Fasten mounting strap/ground clip assembly to junction box.
Connect ground wire.
3. Locate Trac below junction box in desired position, then:
a) Rotate ground clip to accept Trac and push Trac into clip.
b) Fasten Trac to ceiling following instructions supplied with Trac.
c) Trac ends must be terminated with either a dead end (provided)
or continue on to another Trac Section by means of a
Trac Connector.
4. Insert electrical adapter into Trac – rotate 90˚ to locked position to make
electrical contact.
a) Arrow on the electrical adapter must point to the Trac polarity line
when correctly installed.
b) Center line of electrical adapter must be set on center line of
junction box.
5. Pull positive wire from outlet box, and attach to screw terminal
marked “P” (positive).
6. Pull white wire (neutral), on opposite side of Trac, and attach to screw
terminal marked “N” (neutral).
7. Connect mounting strap ground wire to ground wire from junction box.
6. Push excess wire back into outlet box - wire must hug Trac side.
7. Install cover and secure with enclosed screw.
Existing Junction Box
(not supplied)
Screws
Ground
Wire
Trac
Dead End
J-Box Mounting
Strap
Electrical Adapter
Terminal Screws
Cover
Ground
Clip
Cover
Screw
Polarity Line
R29 Floating Feed
Polarity
Line
Set
Screw
Polarity
Arrow
Terminal
Screws
Cover
Feed Connector
1/2" Connector
(not supplied)
R34 Conduit Connector
Existing J
unction
Box
Mounting
Bracket
Mounting
Plate
Screws
R40N Monopoint
R34 Conduit Connector
(For Electrical Feed Away From Junction Box)
Makes electrical connection from, conduit, BX, Romex or Greenfield.
Use at end of Trac Run when wiring.
1. Make sure power is OFF.
2. Remove connector cover.
3. Attach 1/2’’ connector (not supplied) and secure to conduit, BX,
Romex or Greenfield.
4. Insert Conduit Connector fully into Trac section with polarity arrow
pointing toward Trac polarity line, secure with set screw.
5. Attach Trac to ceiling (or wall) following instructions supplied with
the Trac section.
6. Fasten positive wire to screw terminal marked “P”.
7. Fasten neutral white wire to screw terminal marked “N”.
8. Replace cover and secure with screw.
R40N Monopoint
Makes electrical connection at standard junction box. Use to power single Trac
Head at junction box without a Trac section.
1. Make sure power is OFF.
2. Fasten mounting bracket to junction box.
3. Pull wires from junction box and connect to Monopoint wires with wire nuts.
4. Push excess wire back into junction box.
5. Install mounting plate with enclosed screws.
For Juno R Series Trac Connectors, Electrical Feeds and Accessories
INSTALLATION INSTRUCTIONS
3 of 4
1300 S. Wolf Road • Des Plaines, IL 60018 • Phone 800-323-5068 • Visit us at www.acuitybrands.com/juno-trac
©2017 Acuity Brands Lighting, Inc. Rev 3/17 P3069