Instructions / Assembly
INSTALLATION INSTRUCTIONS
JUNO QUICK CONNECT REMODEL LED HOUSINGS - QCR SERIES
One Lithonia Way • Conyers, GA 30012 • Phone 1-800-705-7378
Visit us at www.acuitybrands.com/juno-recessed
© 2022 Acuity Brands Lighting, Inc.
P4922
Rev 01/22
Page 2
USING INSULATION:
Housings are designed for direct contact with insulating materials
which are approved for this application (Fig. 1).
USING GASKETS (only available for some models):
Housings are supplied with pre-installed gaskets for energy savings
and to comply with energy code air leakage requirements per ASTM
E283.
INSTALLATION STEPS
Step 1. Locate center of proposed opening on ceiling and use template
to mark and accurately cut a 4-3/8” (for 4” housings), 5-1/2” (for 5”
housings) or a 6-3/4” (for 6” housings) opening. (Fig. 2).
Step 2. Follow steps 1-4 under electrical connection.
Step 3. Press housing through ceiling opening so it is ush to ceiling
(Fig. 3). Push retention clips outwards until each clip tab clicks into
position.
Note: To remove housing from ceiling, push tab on clip upward to
disengage.
Step 4. For some models, apply tape strips over each of the retention
clips and slots. Cover completely with the tape strips. Use the supplied
strips, do not substitute with duct tape (Fig. 4).
FIGURE 1
FIGURE 2
FIGURE 3
FIGURE 4