Installation Guide
1300 South Wolf Road | Des Plaines, IL 60018 | Phone: 800.323.5068 | www.acuitybrands.com/J6AI
© 2019 Acuity Brands Lighting, Inc. All rights reserved. | JUN_8678.07_0919 | P6190
INSTALLATION INSTRUCTIONS
For J6AI Retrofit Trim Series 1000 Lumen (Patent Pending)
WARNING: Trims must be grounded as outlined
below. Failure to do so can result in electric shock or
undesired operation.
The recessed housing must contain grounded brackets to
support the trim springs and provide electrical ground to
the trim (see Fig. 2). If the housing is grounded but does not
contain spring retaining brackets, contact factory to order an
adapter kit (V6RLTRB). To use this product in an ungrounded
housing, consult factory for additional instructions.
Dedicated Quick Connect Housing
As standard, the primary connection means provided on the
Juno retrofit trims is a connector that is designed to meet the
high efficiency requirements of California T24.The connector
is only intended to be plugged into the mating connector in
Juno housings (Model Numbers: IC23 LEDT24 and IC23R
LEDT24) or into the medium base socket adapter (if provided
with the trim). Use of the J6AI in any other quick connect
housings other than Juno or removing the factory installed
connector is prohibited and voids the product warranty.
CAUTION: Power to the luminaire must be turned
off prior to installing these LED trims. Failure to do
so can cause electric shock, which can result in
injury or death.
Installation
Step 1. Confirm that the J6AI LED trim is compatible
with the recessed housing as outlined previously in
these instructions.
Step 2. Some recessed housings contain an adjustable
plate or bracket that supports the socket. The socket
may need to be detached from the plate/bracket, and the
plate/bracket may need to be removed from the housing
prior to installation of the trim. For detailed instructions
on removing the plate or bracket, refer to manufacturer’s
installation instructions.
Step 3. Installation into existing housings with
medium base sockets: Screw the medium base socket
adaptor into the socket in the recessed housing. Plug the
connector provided on the trim into the mating connector on
the socket adaptor by pushing firmly to ensure connectors
are securely fastened (Fig. 3).
Installation into dedicated quick connect housings: Plug the
connector provided on the trim into the mating connector
in the housing by pushing firmly to ensure connectors are
securely fastened (Fig. 4).
Step 4. Insert trim torsion springs into corresponding
retaining brackets in recessed housing. Carefully push trim
towards ceiling until the springs pull the trim tight.
Step 5. Turn power on to fixture.
J6AI Downlight Retrofit Inserts
The J6AI downlight retrofit trim is designed so that the
decorative cone or baffle inserts can be removed and
replaced in the field. To remove the factory installed
insert (Fig. 5):
1. Locate the quick release slot on the back of the
retrofit trim.
2. Insert a small, flat blade screwdriver into the slot and
push gently against the top of the insert, releasing the
insert from the retrofit trim.
To re-install insert (Fig. 6):
1. Line up the insert with the aperture of the retrofit trim.
2. With even force, push the insert into the retrofit trim
until the insert is fully seated. Confirm that the insert is
securely fastened.
WARRANTY
Limited warranty located at:
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
Technical Services Phone (800) 705-SERV
Recessed
Housing
Typical Spring
Retaining Bracket
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Incandescent
Housing
Quick Connect
Dedicated Quick
Connect Housing
Retrofit Trim
Cone or Baffle
Insert
Quick
Connect
Juno AI Downlight
Medium Base
Socket Adapter
Quick
Release Slot
Juno AI Downlight