Installation Manual
ELECTRICAL FEEDS & MECHANICAL SUPPORTS
FOR USE WITH JUNO FLEX 12 LOW VOLTAGE
EXPOSED CONDUCTOR TRAC LIGHTING SYSTEM
WARNING: MAKE SURE POWER IS OFF BEFORE ASSEMBLY
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
1. Read all instructions before beginning installation.
2. Do not conceal or extend trac through a building wall.
3. Do not install this system in damp or wet locations.
4. To reduce the risk of fire and burns, do not install this
lighting system where the exposed trac conductors
can be shorted or contact any conductive material.
5. To reduce the risk of fire or overheating, make sure all
connections are tight.
6. Do not install any luminiare closer than 6 inches
(15.25cm) from any curtain or similiar combustible
materials.
7. Turn off the electrical power before modifying the
lighting system in any way.
8. For straight 4´ trac installations, two supports are
required, spaced a maximum of 36˝ apart.
9. For straight 8´ trac installations, three supports are
required spaced a maximum of 36˝ apart.
10. Use only with Juno TF5150BL, TF5300BL,
TF5600BL, TF5600BL-24V, TF51200BL-24V
remote mount magnatic transformer power units,
or Juno TF6150E-SL, or TF6300SL surface mount
power units.
11. See the appropriate power unit instruction sheet for
proper installation instructions.
Qualified electricians, in accordance with local electrical
codes, should perform all installations.
TF529 Outrigger Electrical Feed
1. Screw plastic flange to steel strap.
2. Make wire connections in J-Box.
3. Screw strap J-box.
4. Align tapped holes vertically.
5. Slide on canopy and screw to strap.
6. Securely mount trac using large headed screw.
1. Affix to wall with toggle bolts. Align screw
holes vertically for greatest strength.
2. Securely mount trac using large headed
screw.
TF530 Outrigger Support
1. Screw steel strap to J-box, aligning
tapped holes vertically.
2. Make wire connections in J-box.
3. Screw canopy to steel strap.
4. Loosen two screws and insert trac.
Ensure trac is fully seated in canopy
while securely tightening screws.
TF45 Wall Canopy
TF950 Flexible Feed Kit &
TF21 Electrical Feed Cylinder
1. Insert tinned end of wire under screw head as
shown in Fig B. Firmly tighten screw. Repeat steps
for other side.
2. Assemble parts as shown in Fig A.
3. Determine cord length, leaving some slack
& tighten clamp.
4. Mount strap to J-box.
5. Shorten cord as needed and
make connections
in J-box.
6. Mount canopy.
Fig A Fig B
To mount trac to Outriggers, drill a 5/16˝ hole on centerline of trac. After
drilling, ensure that there is no metal burr or shaving that might short
across the trac’s two conductive surfaces.
INSTALLATION INSTRUCTIONS
© 2011 Juno Lighting LLC Rev 8/11 P3002 pg 1 of 2
1300 South Wolf Road • Des Plaines, IL 60018 • PHONE (847) 827-9880 • FAX (847) 827-2925 • www.junolightinggroup.com