Installation Manual

© 2011 Juno Lighting LLC Rev 2/11 P2976 pg 1 of 2
INSTALLATION INSTRUCTIONS
JUNO TYPE WET LOCATION LED MINI STEP LIGHT - LMSW
W
ARNING: For your safety, read and understand instructions completely before starting installation.
Before wiring to power supply, turn off electricity at the fuse or circuit breaker box.
NOTE: Juno recessed fixtures are designed to meet the latest NEC requirements and are listed in full compliance with UL
1598. Before attempting installation of any recessed lighting fixture, check your local electrical building code. This code
sets the wiring standards and installation requirements for your locality and should be understood before starting work.
Juno LMSW fixture is designed for installation in indoor or outdoor wall mount applications and rated for direct contact with
insulating materials. Fixtures may also be used in non-insulated walls. If fixtures are installed outdoors or in a wet location,
the following installation instructions must be followed precisely. Step Lights are designed to mount in standard J-Boxes:
2” x 4” ( 2-1/8” minimum depth) or 4” x 4” (1½” minimum depth) fitted with a single-gang plaster ring 5/8” minimum depth.
J-Boxes and plaster ring are not provided.
WALL PREPARATION
The finished wall cut out can not be more than 1/8” larger on
any side of the J-Box (2” x 4”) or single-gang plaster ring.
If the cut out is greater than that, patch the wall around the
J-Box (2” x 4”) or single-gang plaster ring until it meets the
requirement above.
The front edge of the 2” x 4” J-Box or single-gang plaster ring
when used with 4” x 4” J-Box must be mounted 1/16” behind the
finished wall surface to ensure proper gasket contact pressure
and sealing.
FIXTURE INSTALLATION
VERTICAL ORIENTATION (Figures 1 & 2)
See next section of these instructions for horizontal orientation
installation.
Step 1. Separate the Faceplate (A) from rest of the assembly
by loosening the Set Screw #4-40 (B) (2 Set Screws for Hood)
located on the short (bottom) edge of the Faceplate with the
Allen wrench provided. Fixture is provided ready to be installed
in a vertical orientation. The ground wire (C) is located on the
bottom of the fixture.
Step 2. Make electrical connections. Provide electrical service
to the wiring box according to your local electrical code. Supply
wire insulation must be rated for at least 75˚C.
Connect supply wires to fixture wires with proper size wire nuts
(not supplied), so as to cover all bare current-carrying
conductors. Connect black fixture wire to hot, white to neutral
and green or bare fixture wire to ground.
Place all wiring and connections back in wiring box. Make sure
that supply wires are not pinched or otherwise damaged as the
fixture is installed.
Step 3. Fill the gap between the rough opening and the
J-Box or single-gang plaster ring with waterproof silicone sealant
(GE RTV-162 or equivalent).
Step 4. Apply a generous bead of the waterproof silicone
sealant (GE RTV-162 or equivalent) around the perimeter of the
gasket (D). The bead of sealant is to be between the gasket and
the finished wall surface.
1300 South Wolf Road • Des Plaines, IL 60018 PHONE (847) 827-9880 • FAX (847) 827-2925 • www.junolightinggroup.com
FIGURE 1
FIGURE 2
A
A
E
Notch (M)
at Bottom
G
F
E
D
H
F
B
B
C
SAVE THESE INSTRUCTIONS
(I) Weep Hole
at Bottom

Summary of content (6 pages)