Specification Sheet
1300 S. Wolf Road • Des Plaines, IL 60018 • Phone (847) 827-9880 • Fax (847) 827-2925 • Visit us at www.acuitybrands.com/indy
Printed in U.S.A. ©2017-2021 Acuity Brands Lighting, Inc. Rev. 05/04/21
4 of 12
HYPERBOLIC BEAM SPREAD
Trim 08LM - 40LM 45LM-55LM
L8 HN CS 17˚ 17˚
L8 HN CSS 20˚ 20˚
L8 HN CD 31˚ 31˚
L8 HM CS 37˚ 37˚
L8 HM CSS 37˚ 37˚
L8 HM CD 45˚ 45˚
L8 HW CS 56˚ 56˚
L8 HW CSS 55˚ 55˚
L8 HW CD 64˚ 64˚
PARABOLIC BEAM SPREAD
Trim 08LM - 40LM 45LM-55LM
L8 NPR CS 37° 39°
L8 NPR CSS 36° 44°
L8 NPR CD 56° 61°
L8 P CS 55° 55°
L8 P CSS 58° 61°
L8 P CD 69° 73°
L8 WPR CS 84° 83°
L8 WPR CSS 83° 83°
L8 WPR CD 83° 84°
LIGHT ENGINE 08LM 13LM 15LM 17LM 23LM 28LM 33LM 40LM 45LM 50LM 55LM
120V (50/60HZ)
INPUT CURRENT 0.063 0.098 0.115 0.132 0.180 0.221 0.263 0.334 0.328 0.364 0.410
INPUT WATTAGE 7.53 11.74 13.66 15.82 21.52 26.46 31.62 40.14 39.41 43.54 49.08
THD% 6.42 5.19 4.61 3.86 5.09 5.46 4.43 4.53 6.03 6.03 6.23
POWER FACTOR 0.993 0.993 0.992 0.994 0.994 0.995 0.997 0.998 0.996 0.996 0.996
277V (50/60HZ)
INPUT CURRENT 0.031 0.048 0.056 0.063 0.085 0.100 0.123 0.150 0.153 0.167 0.187
INPUT WATTAGE 7.87 11.84 13.81 15.89 21.65 26.19 31.83 39.68 39.74 43.80 49.02
THD% 12.00 11.62 11.31 11.34 9.93 9.04 10.48 8.79 9.15 8.07 9.85
POWER FACTOR 0.904 0.885 0.887 0.907 0.918 0.943 0.932 0.953 0.934 0.943 0.944
347V (50/60HZ)
INPUT CURRENT 0.025 0.038 0.043 0.050 0.067 0.083 0.099 0.128 * * *
INPUT WATTAGE 8.59 12.99 14.91 17.15 23.20 28.54 34.05 44.12 * * *
THD% 13.05 11.53 10.41 9.69 7.79 7.26 6.54 5.77 * * *
POWER FACTOR 0.987 0.992 0.990 0.991 0.992 0.995 0.993 0.996 * * *
HYPERBOLIC REFLECTOR: L8 HW CS (35K 80CRI)
DELIVERED LUMENS
(L8 HW CS)
833 1,390 1,606 1,828 2,461 2,968 3,454 4,199 4,596 5,030 5,570
EFFICACY (LPW) 111 118 118 116 114 112 109 105 117 116 113
PARABOLIC REFLECTOR: L8 P CS (35K 80CRI)
DELIVERED LUMENS
(L8 P CS)
653 1,089 1,259 1,433 1,929 2,326 2,389 3,292 3,677 4,024 4,456
EFFICACY (LPW) 87 93 92 91 90 88 76 82 93 92 91
PERFORMANCE
OPTICAL DISTRIBUTIONS
LUMEN MULTIPLIERS
CCT MULTIPLIER
2700K 0.90
3000K 0.96
3500K 1.00
4000K 1.01
5000K 1.04
CRI MULTIPLIER
80CRI 1.00
90CRI 0.83
97CRI 0.77
HYPERBOLIC TRIM MULTIPLIER
L8 HN CS 0.96
L8 HN CSS 0.87
L8 HN CD 0.81
L8 HM CS 0.99
L8 HM CSS 0.96
L8 HM CD 0.89
L8 HW CS 1.00
L8 HW CSS 0.98
L8 HW CD 0.87
PARABOLIC TRIM MULTIPLIER
L8 NPR CS 0.94
L8 NPR CSS 1.00
L8 NPR CD 0.94
L8 P CS 1.00
L8 P CSS 0.97
L8 P CD 0.94
L8 WPR CS 0.98
L8 WPR CSS 0.96
L8 WPR CD 0.91
Applying Lumen Multipliers to Calculate Delivered Lumens
Base Fixture Delivered Lumens
(from Performance Table)
x
CCT
Multiplier
x
CRI
Multiplier
x
Trim
Multiplier
=
Delivered Lumens for
Desired Fixture and Reflector
Hyperbolic Reflector Example: LC8S 23LM 30K MVOLT 90CRI G4 ZT HM CD
2461 Lumens x 0.96 x 0.83 x 0.89 = 1745 Lumens
Parabolic Reflector Example: LC8S 23LM 30K MVOLT 90CRI G4 ZT NPR CD
1929 Lumens x 0.96 x 0.83 x 0.94 = 1445 Lumens
J7.2.2G4