Installation Sheet

CABLE MOUNT INSTRUCTIONS
FOR CYLINDERS
1300 S Wolf Road · Des Plaines, IL 60018 · Phone 1-800-705-SERV (7378)· Visit us at www.acuitybrands.com/indy
©2019 Acuity Brands Lighting, Inc. Rev 08/21 065-1214
1 of 4
Technical Services Phone 1-800-705-SERV (7378)
Step 1: Attach mounting strap
(included) to junction box using
screws (2) and tighten.
For Cable Mounting:
Step 2: Slide strain relief over power cord and compress.
Step 3: Insert power cord through largest hole of junction
box cover and secure in place using strain relief.
Step 4: Make wire connections in junction box. To ensure
proper wiring, see wiring diagrams on pages 3 & 4.
Step 5: Place junction box cover over junction box sliding
mounting strap stud through center hole of cover.
Step 6: Attach Swivel Couplingwith cable threaded through
center to mounting strap and tighten to secure junction box
cover firmly to ceiling.
Step 7: Remove reveal from top of cylinder.
Step 8: (A) Insert griplock cable adjustor into center hole of
reveal. (B) Insert power cord and secure in place using
strain relief.
Important: If cord length requires adjusting, determine
length, cut cord and strip leads before attaching to reveal.
Step 9: Loosen cable adjustor.
Step 10: Insert cable into adjustor to desired length and
tighten.