Specification Sheet

1300 S. Wolf Road • Des Plaines, IL 60018 • Phone (847) 827-9880 • Fax (847) 827-2925 • Visit us at www.acuitybrands.com/juno-recessed
Printed in U.S.A. ©2017 Acuity Brands Lighting, Inc. Rev. 08/14/17
3 of 3
PHOTOMETRICS
Fixtures tested to IES recommended standard for solid state lighting per LM-79-08. Photometric performance on a single unit represents a baseline of performance for the fixture. Results may vary in the field.
6” IC 1400 LUMEN LED DOWNLIGHT
NEW CONSTRUCTION
IC22LED (G4 14LM) RECESSED HOUSING
OPEN TRIMS
G1.5.80
INITIAL FOOTCANDLES
(One Unit, 17.4W, 80.3° Beam)
Distance to Illuminated Plane Footcandles Beam
(Feet) Beam Center Diameter
4 59.8 6.7’
6 26.6 10.1’
8 14.9 13.5’
10 9.6 16.9’
100
300
500
700
900
PHOTOMETRIC REPORT
Test Report #: PT10141507R
Catalog No: IC22LED G4 14LM 35K with
24 WWH Trim and standard wide flood optic
Luminaire Spacing Criterion: 1.18
Luminaire LPW: 92
ZONAL LUMEN SUMMARY
Zone Lumens %Lamp %Fixture
0 - 30° 716 N/A 44.8
0 - 40° 1113 N/A 69.7
0 - 60° 1481 N/A 92.7
0 - 90° 1598 N/A 100.0
AVERAGE INITIAL FOOTCANDLES
Multiple Units (Square Array, 60’x60’ room)
Ceiling 80% Wall 50% Floor 20%
Spacing RCR1 RCR3 RCR5
4.0´ 108 88 74
5.0´ 69 56 47
6.0´ 48 39 33
7.0´ 39 32 27
8.0´ 31 25 21
9.0´ 23 19 16
10.0´ 17 14 12
CANDLEPOWER
DISTRIBUTION
(Candelas)
Degrees
Vertical 0˚
0 956
5 949
15 898
25 811
35 650
45 307
55 135
65 65
75 38
85 10
90 0
Multiplier: 27K - 0.93
30K - 0.97
40K - 1.02
LUMINANCE (Average cd/m
2
)
Average
Degrees Luminance
45 25776
55 13943
65 9155
75 8740
85 6595
INITIAL FOOTCANDLES
(One Unit, 17.4W, 58° Beam)
Distance to Illuminated Plane Footcandles Beam
(Feet) Beam Center Diameter
4 106.0 4.4’
6 47.1 6.7’
8 26.5 8.9’
10 17.0 11.1’
200
600
1000
1400
1800
PHOTOMETRIC REPORT
Test Report #: 25978R
Catalog No: IC22LED G4 14LM 35K with
27 CWH Trim and standard wide flood optic
Luminaire Spacing Criterion: 0.78
Luminaire LPW: 98
ZONAL LUMEN SUMMARY
Zone Lumens %Lamp %Fixture
0 - 30° 918 N/A 53.8
0 - 40° 1336 N/A 78.3
0 - 60° 1684 N/A 98.7
0 - 90° 1707 N/A 100.0
AVERAGE INITIAL FOOTCANDLES
Multiple Units (Square Array, 60’x60’ room)
Ceiling 80% Wall 50% Floor 20%
Spacing RCR1 RCR3 RCR5
4.0´ 117 98 84
5.0´ 75 63 54
6.0´ 52 44 37
7.0´ 42 35 30
8.0´ 33 28 24
9.0´ 26 21 18
10.0´ 19 16 13
CANDLEPOWER
DISTRIBUTION
(Candelas)
Degrees
Vertical 0˚
0 1696
5 1589
15 1206
25 946
35 677
45 323
55 103
65 21
75 0
85 0
90 0
Multiplier: 27K - 0.93
30K - 0.97
40K - 1.02
LUMINANCE (Average cd/m
2
)
Average
Degrees Luminance
45 27283
55 10684
65 2947
75 0
85 0