Specification Sheet

1300 S. Wolf Road • Des Plaines, IL 60018 • Phone (847) 827-9880 • Fax (847) 827-2925 • Visit us at www.acuitybrands.com/juno-recessed
Printed in U.S.A. ©2017 Acuity Brands Lighting, Inc. Rev. 03/01/17
3 of 3
PHOTOMETRICS
Fixtures tested to IES recommended standard for solid state lighting per LM-79-08. Photometric performance on a single unit represents a baseline of performance for the fixture. Results may vary in the field.
6” IC 600 LUMEN LED DOWNLIGHT
NEW CONSTRUCTION
IC22LED (G4 06LM) RECESSED HOUSING
OPEN TRIMS
G1.5.42
INITIAL FOOTCANDLES
(One Unit, 8.6W , 78.8° Beam)
Distance to Illuminated Plane Footcandles Beam
(Feet) Beam Center Diameter
4 28.4 6.6’
6 12.6 9.9’
8 7.1 13.1’
10 4.5 16.4’
100
200
300
400
500
PHOTOMETRIC REPORT
Test Report #: PT02141401
Catalog No: IC22LED G4 06LM 35K with
24 WWH Trim and standard wide flood optic
Luminaire Spacing Criterion: 1.16
Luminaire LPW: 85
ZONAL LUMEN SUMMARY
Zone Lumens %Lamp %Fixture
0 - 30° 336 N/A 46.0
0 - 40° 517 N/A 70.8
0 - 60° 679 N/A 92.9
0 - 90° 731 N/A 100.0
AVERAGE INITIAL FOOTCANDLES
Multiple Units (Square Array, 60’x60’ room)
Ceiling 80% Wall 50% Floor 20%
Spacing RCR1 RCR3 RCR5
4.0´ 49 41 34
5.0´ 32 26 22
6.0´ 22 18 15
7.0´ 18 15 12
8.0´ 14 12 10
9.0´ 11 9 7
10.0´ 8 7 5
CANDLEPOWER
DISTRIBUTION
(Candelas)
Degrees
Vertical 0˚
0 455
5 451
15 424
25 378
35 297
45 134
55 59
65 29
75 17
85 4
90 0
Multiplier: 27K - 0.89
30K - 0.94
40K - 1.03
LUMINANCE (Average cd/m
2
)
Average
Degrees Luminance
45 10410
55 5634
65 3758
75 3756
85 2451
INITIAL FOOTCANDLES
(One Unit, 8.6W , 58.1° Beam)
Distance to Illuminated Plane Footcandles Beam
(Feet) Beam Center Diameter
4 49.8 4.4’
6 22.2 6.7’
8 12.5 8.9’
10 8.0 11.1’
100
300
500
700
900
PHOTOMETRIC REPORT
Test Report #: LTL25975R
Catalog No: IC22LED G4 06LM 35K with
27 CWH Trim and standard wide flood optic
Luminaire Spacing Criterion: 0.78
Luminaire LPW: 93
ZONAL LUMEN SUMMARY
Zone Lumens %Lamp %Fixture
0 - 30° 433 N/A 53.9
0 - 40° 629 N/A 78.3
0 - 60° 793 N/A 98.7
0 - 90° 803 N/A 100.0
AVERAGE INITIAL FOOTCANDLES
Multiple Units (Square Array, 60’x60’ room)
Ceiling 80% Wall 50% Floor 20%
Spacing RCR1 RCR3 RCR5
4.0´ 55 46 40
5.0´ 35 30 25
6.0´ 25 21 18
7.0´ 20 17 14
8.0´ 16 13 11
9.0´ 12 10 9
10.0´ 9 7 6
CANDLEPOWER
DISTRIBUTION
(Candelas)
Degrees
Vertical 0˚
0 797
5 749
15 569
25 446
35 318
45 152
55 48
65 10
75 0
85 0
90 0
Multiplier: 27K - 0.89
30K - 0.94
40K - 1.03
LUMINANCE (Average cd/m
2
)
Average
Degrees Luminance
45 12833
55 5012
65 1389
75 0
85 0