PHOTOMETRICS
Fixtures tested to IES recommended standard for solid state lighting per LM-79-08. Photometric performance on a single unit represents a baseline of performance for the fixture. Results may vary in the field.
4” IC 600 LUMEN LED DOWNLIGHT
REMODEL
IC1RLED (G4 06LM) RECESSED HOUSING
OPEN TRIMS
G1.7.15
150
450
750
1050
1350
INITIAL FOOTCANDLES
(One Unit, 8.7W , 44.2° Beam)
Distance to Illuminated Plane Footcandles Beam
(Feet) Beam Center Diameter
4 65.9 3.2’
6 29.3 4.9’
8 16.5 6.5’
10 10.6 8.1’
PHOTOMETRIC REPORT
Test Report #: PT02141303R
Catalog No: IC1RLED G4 06LM 35K
90CRI 120 with 14 WWH Trim
Luminaire Spacing Criterion: 0.72
Luminaire LPW: 76
ZONAL LUMEN SUMMARY
Zone Lumens %Lamp %Fixture
0 - 30° 507 N/A 76.5
0 - 40° 603 N/A 91.0
0 - 60° 649 N/A 98.0
0 - 90° 663 N/A 100.0
AVERAGE INITIAL FOOTCANDLES
Multiple Units (Square Array, 60’x60’ room)
Ceiling 80% Wall 50% Floor 20%
Spacing RCR1 RCR3 RCR5
4.0´ 46 40 35
5.0´ 29 26 23
6.0´ 20 18 16
7.0´ 17 14 13
8.0´ 13 11 10
9.0´ 10 9 8
10.0´ 7 6 6
CANDLEPOWER
DISTRIBUTION
(Candelas)
Degrees
Vertical 0˚
0 1055
5 1026
15 791
25 425
35 146
45 38
55 16
65 7
75 5
85 0
90 0
Multiplier: 27K - 0.89
30K - 0.94
40K - 1.03
LUMINANCE (Average cd/m
2
)
Average
Degrees Luminance
45 8859
55 4517
65 2855
75 2880
85 1425
150
450
750
1050
1350
INITIAL FOOTCANDLES
(One Unit, 8.7W , 43.9° Beam)
Distance to Illuminated Plane Footcandles Beam
(Feet) Beam Center Diameter
4 67.0 3.2’
6 29.8 4.8’
8 16.8 6.4’
10 10.7 8.1’
PHOTOMETRIC REPORT
Test Report #: LTL26327R
Catalog No: IC1RLED G4 06LM 35K
90CRI 120 with 17 CWH Trim
Luminaire Spacing Criterion: 0.70
Luminaire LPW: 80
ZONAL LUMEN SUMMARY
Zone Lumens %Lamp %Fixture
0 - 30° 516 N/A 73.9
0 - 40° 631 N/A 90.5
0 - 60° 695 N/A 99.6
0 - 90° 698 N/A 100.0
AVERAGE INITIAL FOOTCANDLES
Multiple Units (Square Array, 60’x60’ room)
Ceiling 80% Wall 50% Floor 20%
Spacing RCR1 RCR3 RCR5
4.0´ 48 42 37
5.0´ 31 27 24
6.0´ 22 19 16
7.0´ 17 15 13
8.0´ 14 12 11
9.0´ 11 9 8
10.0´ 8 7 6
CANDLEPOWER
DISTRIBUTION
(Candelas)
Degrees
Vertical 0˚
0 1072
5 1054
15 785
25 441
35 181
45 59
55 18
65 0
75 0
85 0
90 0
Multiplier: 27K - 0.89
30K - 0.94
40K - 1.03
LUMINANCE (Average cd/m
2
)
Average
Degrees Luminance
45 13321
55 5080
65 766
75 0
85 0