Specification Sheet

1300 S. Wolf Road • Des Plaines, IL 60018 • Phone (847) 827-9880 • Fax (847) 827-2925 • Visit us at www.acuitybrands.com/juno-recessed
Printed in U.S.A. ©2017 Acuity Brands Lighting, Inc. Rev. 08/7/17
3 of 3
PHOTOMETRICS
Fixtures tested to IES recommended standard for solid state lighting per LM-79-08. Photometric performance on a single unit represents a baseline of performance for the fixture. Results may vary in the field.
4” IC 900 LUMEN LED DOWNLIGHT
REMODEL
IC1RLED (G4 09LM) RECESSED HOUSING
OPEN TRIMS
G1.7.43
INITIAL FOOTCANDLES
(One Unit, 11.6W , 44.2° Beam)
Distance to Illuminated Plane Footcandles Beam
(Feet) Beam Center Diameter
4 93.2 3.2’
6 41.4 4.9’
8 23.3 6.5’
10 14.9 8.1’
150
450
750
1050
1350
PHOTOMETRIC REPORT
Test Report #: PT02141303R
Catalog No: IC1RLED G4 09LM 35K
90CRI 120 with 14 WWH Trim
Luminaire Spacing Criterion: 0.72
Luminaire LPW: 81
ZONAL LUMEN SUMMARY
Zone Lumens %Lamp %Fixture
0 - 30° 717 N/A 76.5
0 - 40° 852 N/A 91.0
0 - 60° 917 N/A 98.0
0 - 90° 936 N/A 100.0
AVERAGE INITIAL FOOTCANDLES
Multiple Units (Square Array, 60’x60’ room)
Ceiling 80% Wall 50% Floor 20%
Spacing RCR1 RCR3 RCR5
4.0´ 65 57 50
5.0´ 42 36 32
6.0´ 29 25 22
7.0´ 23 20 18
8.0´ 18 16 14
9.0´ 14 12 11
10.0´ 10 9 8
CANDLEPOWER
DISTRIBUTION
(Candelas)
Degrees
Vertical 0˚
0 1491
5 1449
15 1118
25 600
35 206
45 54
55 22
65 10
75 6
85 1
90 0
Multiplier: 27K - 0.89
30K - 0.94
40K - 1.03
LUMINANCE (Average cd/m
2
)
Average
Degrees Luminance
45 12517
55 6382
65 4034
75 4069
85 2014
INITIAL FOOTCANDLES
(One Unit, 11.6W , 43.9° Beam)
Distance to Illuminated Plane Footcandles Beam
(Feet) Beam Center Diameter
4 94.3 3.2’
6 41.9 4.8’
8 23.6 6.4’
10 15.1 8.1’
200
600
1000
1400
1800
PHOTOMETRIC REPORT
Test Report #: LTL26327R
Catalog No: IC1RLED G4 09LM 35K
90CRI 120 with 17 CWH Trim
Luminaire Spacing Criterion: 0.70
Luminaire LPW: 85
ZONAL LUMEN SUMMARY
Zone Lumens %Lamp %Fixture
0 - 30° 725 N/A 73.9
0 - 40° 887 N/A 90.5
0 - 60° 977 N/A 99.6
0 - 90° 981 N/A 100.0
AVERAGE INITIAL FOOTCANDLES
Multiple Units (Square Array, 60’x60’ room)
Ceiling 80% Wall 50% Floor 20%
Spacing RCR1 RCR3 RCR5
4.0´ 68 59 52
5.0´ 44 38 33
6.0´ 30 26 23
7.0´ 25 21 19
8.0´ 19 17 15
9.0´ 15 13 11
10.0´ 11 10 8
CANDLEPOWER
DISTRIBUTION
(Candelas)
Degrees
Vertical 0˚
0 1508
5 1482
15 1104
25 620
35 254
45 82
55 26
65 3
75 0
85 0
90 0
Multiplier: 27K - 0.89
30K - 0.94
40K - 1.03
LUMINANCE (Average cd/m
2
)
Average
Degrees Luminance
45 18733
55 7144
65 1077
75 0
85 0