Installation Sheet
JUNO TYPE IC & TC RECESSED HOUSING
INSTALLATION INTO
SUSPENDED CEILING
Step 1. Locate center of proposed opening on
ceiling tile and cut appropriate sized hole.*
Step 2. Place ceiling tile in T-bar grid.
Step 3. Place fixture into position and snap bar
hanger foot with integral T-bar clips onto T-bars
(Fig. 7). Additional holes provided for securing
with wire or screws (Fig. 7).
Step 4. Follow Steps 1-4 under Electrical
Connection.
ELECTRICAL CONNECTION
INSTRUCTIONS
Step 1. Provide electrical service according
to your local electrical code to the wiring box
located on the plaster frame. Supply wire
insulation must be rated for at least 90°C.
Step 2. Remove wiring box cover. Remove the
appropriate knock-out(s) to accommodate the
type of electrical service to be used/allowed by
your local electrical code (Fig. 9):
Metal Conduit. Remove appropriate round
knock-out(s) and connect conduit to wiring box
with proper connectors (not supplied).
Non-Metallic (NM) Cable. Remove
appropriate D-shaped NM cable knock-out(s).
Insert NM cable through NM cable trap and
make a 90˚ L-shaped bend in cable as shown
(Fig. 10).
Step 3. J-Box with Quick Connectors: Strip
supply wire 3/8”, insert each supply wire into
appropriate junction box connector. Connect
black fixture wire to hot, white fixture wire to
neutral and green fixture wire to ground.
Step 4. Place all wiring and connectors back in
wiring box and replace cover.
Figure 7
Figure 9
Figure 8
* Note: Cut a 4-1/2” (for 4” housings), 5-5/8”
(for 5” housings) or 6
-
-7/8” (for 6” housings)
opening. For sloped ceiling housings, use the
provided oval hole template.
Figure 11
TRIM INSTALLATION
Install trim using coil, leaf, torsion, or push-in
springs as provided. Remove socket paint
protector cover and install proper lamp as
listed on housing label.
Figure 10
Black
Lamp Socket
Thermal Protector
White
120V
Mark means lamp
contains mercury.
Follow disposal laws.
See www.lamprecycle.org
Hg
Metal
Conduit
Non-
Metallic
Cable
INSTALLATION INSTRUCTIONS
2 of 2
1300 S. Wolf Road • Des Plaines, IL 60018 • Phone 800-323-5068 • Visit us at www.acuitybrands.com/juno-recessed
©2017 Acuity Brands Lighting, Inc Rev 3/17 P5142
WARRANTY
1-year limited warranty. Complete warranty terms located at
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
Technical Services Phone (888) 387-2212