User manual
15GB
12a
Vr
ø 150
ø 150
14.1
15
Mounting the hood body
• Before attaching the hood body, tighten the two
screws Vr located on the hood body mounting
points.
• Hook the hood body onto the screws 12a.
• Fully tighten support screws 12a
• Adjust screws Vr to level the hood body.
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney using either a flexible or rigid
pipe ø 150 mm, the choice of which is left to the installer.
• Fix the pipe in position using sufficient pipe
clamps (not supplied).
• Remove any activated charcoal filters.
RECIRCULATION VERSION AIR OUTLET
• Put connection 15 into the connection support
7.3.
• Insert the connection extension pieces laterally
14.1 in connection 15.
• Make sure that the outlet of the extension pieces
14.1 is horizontally and vertically aligned with
the chimney outlets.
• Connect the air outlet connection 15 to the hood
body outlet using either a flexible or rigid pipe
ø 150 mm, the choice of which is left to the
installer.
• Ensure that the activated charcoal filters have
been inserted.
ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm.