Installation Instructions

Flue systems
6 720 645 817 (2010/09)
83
Flue accessories
Flue lengths
Description
Ø125mm
(Æ page 92 ff.)
Ø160mm
(Æ page 97 ff.)
Ø200mm
(Æ page 103 ff.)
Ø250mm
(Æ page 109 ff.)
Boiler flue connection, 87° bend AZB 1350
AZB 1350
AZB 1351
AZB 1351 AZB 1351
Boiler flue connection, straight AZB 1352
AZB 1352
AZB 1353
AZB 1353 AZB 1353
1 Vertical flue gas routing AZB 1323 AZB 1324 AZB 1325 AZB 1326
2 Universal roof tile
AZB 923
AZB 925
AZB 1320
AZB 1321
2 Roof tile, special AZB 1341 AZB 1342
3
Extension pipe 0.5 m
Extension pipe 1 m
Extension pipe 2 m
AZB 977
AZB 718/1
AZB 985
AZB 978
AZB 982
AZB 986
AZB 979
AZB 983
AZB 987
AZB 980
AZB 984
AZB 988
4 Inspection aperture AZB 720/1 AZB 994 AZB 995 AZB 996
5 87° bend (90°) AZB 934 AZB 974 AZB 975 AZB 976
45° bend AZB 940 AZB 970 AZB 971 AZB 972
30° bend AZB 724/1 AZB 966 AZB 967 AZB 968
15° bend AZB 719/1 AZB 964
87° bend with inspection aperture AZB 997 AZB 998 AZB 999 AZB 1000
6 Support for flue system AZB 1327 AZB 1328 AZB 1329 AZB 1330
7 Flat roof flange AZ 136 AZB 1322 AZB 1344 AZB 1345
Reduction adaptor AZB 1346 AZB 1309 AZB 1347
Enlargement adaptor AZB 961 AZB 962
Tab. 49
Maximum permissible effective height of flue L in m
1)
1) Basis for calculation: Overall length of the connection piece 1.5 m
Suprapur DN 125 DN 160 DN 200 DN 250
KBR 120-3 A 27 50
KBR 160-3 A 10 50
KBR 200-3 A 41
KBR 240-3 A 23 50
KBR 280-3 A 12 50
MKB 240-3 A 50
MKB 320-3 A 32
MKB 400-3 A 50
MKB 480-3 A 50
MKB 560-3 A 38
Tab. 50 Internal diameter and effective height of flues according to the requirements of DIN-EN 13381-1
Bend Equivalent pipe length
90° 2m
15° - 45° 1m
Tab. 51 Equivalent pipe lengths of bends