Installation Instructions

Heating controls
6 720 645 817 (2010/09)
57
ISM 1 Application
Solar module for solar DHW heating in conjunction with Fx controller
Communication with the condensing boiler and controller via 2-wire BUS
3 switching outputs 230 V AC, 50 Hz, 2.5 A, max. 80 W
3 sensor inputs
Function status LED
Installation
Top-hat profile rail installation or wall mounting (height/width/depth: 110/156/55 mm)
Power supply 230 V AC, 50 Hz, 2.5 A
Standard delivery
2 x cylinder temperature sensors
1 x collector temperature sensor
Part no. 7 719 002 740
ISM 2 Application
Solar module for solar DHW heating and solar central heating backup in conjunction
with Fx controller
Communication with the condensing boiler and controller via 2-wire BUS
6 switching outputs 230 V AC, 50 Hz, 2.5 A, max. 80 W
6 sensor inputs
Function status LED
Installation
Top-hat profile rail installation or wall mounting (height/width/depth: 155/246/57 mm)
Power supply 230 V AC, 50 Hz, 2.5 A
Standard delivery
1 x cylinder temperature sensor
1 x collector temperature sensor
1 x flow temperature sensor
Part no. 7 719 002 741
IEM Application
Extension module for integrating extended heating circuits, e.g. convector heaters or
swimming pool controllers in conjunction with FW 500
Communication with the controller via 2-wire BUS
Three switching outputs 230 V AC, 50 Hz, max. 200 W per connection
Three floating inputs
Function status LED
Installation
Top-hat profile rail installation or wall mounting (height/width/depth: 110/156/55 mm)
Power supply 230 V AC, 50 Hz, 4 A
Part no. 7 719 002 968
Tab. 29