Installation Instructions
Heating controls
6 720 645 817 (2010/09)
57
ISM 1 Application
• Solar module for solar DHW heating in conjunction with Fx controller
• Communication with the condensing boiler and controller via 2-wire BUS
• 3 switching outputs 230 V AC, 50 Hz, 2.5 A, max. 80 W
• 3 sensor inputs
• Function status LED
Installation
• Top-hat profile rail installation or wall mounting (height/width/depth: 110/156/55 mm)
• Power supply 230 V AC, 50 Hz, 2.5 A
Standard delivery
• 2 x cylinder temperature sensors
• 1 x collector temperature sensor
Part no. 7 719 002 740
ISM 2 Application
• Solar module for solar DHW heating and solar central heating backup in conjunction
with Fx controller
• Communication with the condensing boiler and controller via 2-wire BUS
• 6 switching outputs 230 V AC, 50 Hz, 2.5 A, max. 80 W
• 6 sensor inputs
• Function status LED
Installation
• Top-hat profile rail installation or wall mounting (height/width/depth: 155/246/57 mm)
• Power supply 230 V AC, 50 Hz, 2.5 A
Standard delivery
• 1 x cylinder temperature sensor
• 1 x collector temperature sensor
• 1 x flow temperature sensor
Part no. 7 719 002 741
IEM Application
• Extension module for integrating extended heating circuits, e.g. convector heaters or
swimming pool controllers in conjunction with FW 500
• Communication with the controller via 2-wire BUS
• Three switching outputs 230 V AC, 50 Hz, max. 200 W per connection
• Three floating inputs
• Function status LED
Installation
• Top-hat profile rail installation or wall mounting (height/width/depth: 110/156/55 mm)
• Power supply 230 V AC, 50 Hz, 4 A
Part no. 7 719 002 968
Tab. 29