Installation Instructions

Heating controls
6 720 645 817 (2010/09)
54
FW 200 Application
Weather-compensated flow temperature controller
Constant output control
Communication with the condensing boiler via 2-wire BUS
Function
2-wire BUS technology, reverse polarity protected connection
Controls two mixed heating circuits without remote control
Up to four mixed heating circuits possible (FW 200 + FB 100 + two IPM 2)
DHW program for DHW cylinder (adjustable time and temperature)
Solar DHW heating (with ISM 1)
Solar central heating backup (with ISM 2)
Cascade circuit (up to four appliances)
Optional solar optimisation of heating circuit and DHW
Optional FB 10 or FB 100 remote controls
7-day program with six switching times per day for two heating circuits (mixed or
unmixed) and DHW heating
Date and time, automatic summer/winter changeover
Fault codes displayed in plain text
Switching of IPM1, IPM2, ISM1 and ISM2 modules (for two mixed heating circuits,
solar central heating backup)
Preinstalled programs adjustable to customer's requirements
Holiday function with date entry
Intuitive menu prompts with plain text support
Thermal disinfection possible
DHW circulation pump program
Screed drying program
Room temperature hook-up
Optimised heating curves
Heat-up optimisation and adjustable heat-up speed (slow, normal, fast)
Info function
Remote management via Netcom 100
Installation
Wall mounting (height/width/depth: 119/134/45 mm)
Power supply 15 V via 2-wire BUS
Accessories
IPM 1, IPM 2 load switching modules
ISM 1, ISM 2 solar modules
FB 10 remote control
FB 100 remote control with plain text display
ICM cascade module (may be used as 0-10 V interface)
Part no. 7 719 002 507
Tab. 28