Installation Instructions

Heating controls
6 720 645 817 (2010/09)
53
8.3 Weather-compensated controllers
FW 100 Application
Weather-compensated flow temperature controller
Constant output control
Communication with the heat source via 2-wire BUS
Function
2-wire BUS technology, reverse polarity protected connection
Controls one mixed or unmixed heating circuit
DHW program for DHW cylinder (adjustable time and temperature)
Solar DHW heating (with ISM 1)
Solar-optimised heating circuit and DHW heating as options
Optional FB 10 or FB 100 remote controls
7-day program with six switching times per day for one mixed or one unmixed heating
circuit and DHW heating
Date and time, automatic summer/winter changeover
Fault codes displayed in plain text
Switching modules IPM 1, ISM 1 (for mixed heating circuit, solar DHW heating)
Preinstalled programs adjustable to customer's requirements
Holiday function with date entry
Intuitive menu prompts with plain text support
Thermal disinfection possible
DHW circulation pump program
Screed drying program
Room temperature hook-up
Optimised heating curves
Adjustable heat-up speed (slow, normal, fast)
Info function
Remote management via Netcom 100
Installation
Wall mounting (height/width/depth: 119/134/45 mm)
Power supply 15 V via 2-wire BUS
Accessories
IPM 1 load switching module
ISM 1 solar module
FB 10 remote control
FB 100 remote control with plain text display
Part no. 7 719 002 923
Tab. 28