Installation Instructions
Heating controls
6 720 645 817 (2010/09)
52
8.2 Overview of the BUS-regulated controller functions
Weather-compensated controller
Controller FW 100 FW 200 FW 500
1 unmixed heating circuit y y y
1 mixed heating circuit
y
(with IPM 1)
y
(with IPM 1)
y
(with IPM 1)
2 mixed heating circuits –
y
(with IPM 2)
y
(with IPM 2)
4 mixed heating circuits –
y
(with 2 IPM 2+ 2 FB 100)
y
(with 2 IPM 2+ 2 FB 100)
10 mixed heating circuits – –
y
(with 5 IPM 2+ 8 FB 100)
DHW heating via cylinder
(time program)
y
(with IPM 1)
y
(with IPM 1)
y
(with IPM 1)
Control of several DHW
cylinders (time program)
– –
y
(with IPM 2)
DHW circulation (time
program)
y y y
Solar DHW heating
y
(with ISM 1)
y
(with ISM 1)
y
(with ISM 1)
Solar central heating backup +
DHW heating
–
y
(with ISM 2)
y
(with ISM 2)
Cascade circuit with
up to 4 appliances
–
y
(with ICM)
y
(with ICM)
Screed drying program y y y
Automatic summer/winter
changeover
y y y
Thermal disinfection y y y
Solar optimisation -
DHW heating
y y y
Solar optimisation -
heating circuit
y y y
Convector heater and
swimming pool control
– –
y
(with IEM)
Heat-up optimisation – – –
Room temperature hook-up y y y
Heating curve optimisation y y y
Remote management
(Netcom 100)
y y y
System info y y y
Holiday function y y y
Tab. 27