Installation Instructions

Specification
6 720 645 817 (2010/09)
27
2.3 Installed dimensions
Wherever possible, site the Suprapur gas condensing
boiler with the recommended wall clearances
(Æ Fig. 12). This ensures good accessibility for
installation, maintenance and service.
A reduction of the minimum clearances makes boiler
access more difficult.
2.3.1 Single appliance Suprapur KBR ...
Fig. 12 Installed dimensions Suprapur single boiler
Minimum handling details
A
C
B
D
6 720 644 748-07.1O
Dimension Wall clearance in mm
A 700/500
B 700/550
C 500/100
D 700/500
Tab. 14 Recommended/minimum wall clearances
Unit KBR 120-3 A KBR 160-3 A KBR 200-3 A KBR 240-3 A KBR 280-3 A
Minimum depth mm 612 612 612 612 612
Minimum width mm 855 1065 1065 1275 1275
Minimum height mm 1405 1405 1405 1405 1405
Minimum weight kg 190 219 244 277 307
Tab. 15 Minimum handling details Suprapur single boiler