Spec Sheet
6
Data SheetMX960, MX480, MX240, MX104 and MX80 3D Universal Edge Routers
Specifications
MX960 MX480 MX240 MX104 MX80-MX5
Layout
System capacity 10.56 Tbps 5.76 Tbps 1.92 Tbps 80 Gbps 80 Gbps
19
Slot orientation Vertical Horizontal Horizontal Horizontal Horizontal
Mounting Front or center Front or center Front or center Front or center Front or center
Physical
Specification
Dimensions
(W x H x D)
17.37 x 27.75 x 23
in (44.11 x 70.49 x
58.42 cm)
17.45 x 14 x 24.5
in (44.3 x 35.6 x
62.2 cm)
17.45 x 8.71 x 24.5
(44.3 x 22.1 x 62.2
cm)
17.22 x 9.46 x
6.09 in (43.7 x 24
x 15.47 cm)
17.5 x 3.5 x 23.46 in
(44.5 x 8.9 x 59.6
cm)
Weight fully loaded 334 lb/151.6 kg 180 lbs/81.6 kg 130 lb/59 kg 32 lb/14.5 kg 30 lb/13.7 kg
Weight unloaded 150 lbs/68.1 kg 65.5 lbs/29.7 kg 52 lbs/23.6 kg N/A N/A
Routing Engine
Default memory 2x16 MB NOR
flash storage;
64 GB of DDR4
RAM; 2x50 GB
SSD
2x16 MB NOR
flash storage;
64 GB of DDR4
RAM; 2x50 GB
SSD
2x16 MB NOR
flash storage;
64 GB of DDR4
RAM; 2x50 GB
SSD
4 MB boot flash;
8 GB of NAND
Flash; 4 GB of
DDR3 RAM
8 MB boot flash; 4
GB on NAND flash
storage; 2 GB of
DDR2 RAM
Number of cores 6 cores 6 cores 6 cores 1 core 1 core
Redundancy Components
Power supplies,
REs, fans
Power supplies and
fans
Power
Power input [AC] 100 to 240 V AC 100 to 240 V AC 100 to 240 V AC 100 to 240 V AC 100 to 240 V AC
Power input [DC] -40 to -72 V DC -40 to -72 V DC -40 to -72 V DC -40 to -72 V DC -40 to -72 V DC
Typical power draw
(AC)
6520 W 3470 W 1860 W 325 W 365 W
Typical power draw
(DC)
6670 W 3150 W 1690 W 350 W 310 W
Environmental
Air flow Front to back Side to side Side to side Side to side
[forced air]
Side to side [forced
air]
Operating
temperature
32°-104°F (0°-
40°C)
32°-104°F (0°-
40°C)
32°-104°F (0°-
40°C)
-40° to 149°F
(-40° to 65°C)
32°-104°F (0°-
40°C)
Operating humidity 5% to 90% 5% to 90% 5% to 90% 5% to 90% 5% to 90%
Operating altitude 10,000
(3048 m)
10,000
(3048 m)
10,000
(3048 m)
6,000
(1,900 m)
13,000
(4,000 m)
Certifications NEBS
- GR-1089-Core
(2006) EMC and
Electrical Safety
- Common
Bonding Network
(CBN)
- National
Electrical Code
(NEC)
- GR-1089-Core
(2006) EMC and
Electrical Safety
- Common
Bonding Network
(CBN)
- National
Electrical Code
(NEC)
- GR-1089-Core
(2006) EMC and
Electrical Safety
- Common
Bonding Network
(CBN)
- National
Electrical Code
(NEC)
- SR-3580
(2007) NEBS
Criteria Levels
(Level 3
Compliance)
- GR-63-
Core (2006)
NEBS Physical
Protection
- GR-1089-Core
(2006) EMC and
Electrical Safety
- E26GR-3108-
CORE Issue 2,
December 2008
- IEEE 1613: 2009
- IEC 61850-3:
2013
• GR-63-Core:NEBS,
Physical Protection
• GR-1089-Core:EMC
and Electrical Safety
for Network
Telecommunications
Equipment