Datasheet

5
Specifications
Physical Specifications
Dimensions (W x H x D):
14.40 x 1.59 x 20.51 in (36.58 x 4.04 x 52.09 cm)
Weight:
EX8200-48T: 11.26 lb (5.11 kg)
EX8200-48F: 13.26 lb (6.01 kg)
EX8200-8XS: 15.30 lb (6.94 kg)
EX8200-40XS: 15.30 lb (6.94 kg)
Layer 2 Switching
GVRP
Physical port redundancy: Redundant trunk group (RTG)
STP/RSTP (802.1D-2004)
VSTP (Compatible with PVST+)
STP enable/disable per port
MSTP (802.1Q-2003)
Number of MST instances supported: 64
LLDP
RVI (Routed VLAN Interface)
FCoE- and CEE-capable (EX8200-40XS)*
Layer 3 Features: IPv4
Routing protocols: RIPv1/v2, OSPF, BGP, IS-IS
Static routing
Routing policy
Bidirectional Forwarding Detection
Layer 3 redundancy: VRRP
Layer 3 sub-interfaces
IP directed broadcast
Layer 3 Features: IPv6
Routing protocols: RIPng, OSPFv3, BGP, IS-IS, PIM, MLD
Static routing
Routing policy
Bidirectional Forwarding Detection
Layer 3 redundancy: VRRPv6
Layer 3 sub-interfaces
IP directed broadcast
Access Control Lists (ACLs) (Junos
®
firewall filters)
Port-based ACL (PACL) Ingress and Egress
VLAN-based ACL (VACL) Ingress and Egress
Router-based ACL (RACL) Ingress and Egress
ACL counters
Layer 2-4 classification criteria: Interface, MAC address,
Ethertype, 802.1p, VLAN, IP address, DSCP/IP Precedence, TCP/
UDP port numbers, etc.
Control Plane DoS protection
Link Aggregation
802.3ad (LACP) support:
- Number of LAGs supported: 255
- Max number of ports per LAG: 12
LAG load-sharing algorithm:
- IP: S/D MAC, S/D IP
- TCP/UDP: S/D MAC, S/D IP, S/D Port
- Non-IP: S/D MAC
Tagged ports support in LAG
QoS
Ingress policing: single rate 2 color
Hardware queues per port: 8
Scheduling methods (egress): Strict priority (SP), Shaped
Deficit Weighted Round-Robin (SDWRR)
802.1p, DSCP/IP Precedence trust, classification, and marking
Layer 2-4 classification criteria: Interface, MAC address,
Ethertype, 802.1p, VLAN, IP address, DSCP/IP Precedence,
TCP/UDP port numbers, etc.
Egress WRED: Per queue per CoS threshold
CoS-based fabric ingress and egress queuing
Environmental Ranges
Operating temperature: 32° to 10 F ( to 40° C)
Storage temperature: -4 to 158° F (-40° to 7 C)
Operating altitude: up to 10,000 ft (3,048 m)
Non-operating altitude: up to 16,000 ft (4,877 m)
Relative humidity operating: 5% to 90% (non-condensing)
Relative humidity non-operating: 0% to 95% (non-condensing)
Safety and Compliance
CSA 60950-1 (2003) Safety of Information Technology
Equipment
UL 60950-1 (2003) Safety of Information Technology
Equipment
EN 60950-1 (2001) Safety of Information Technology
Equipment
IEC 60950-1 (2001) Safety of Information Technology
Equipment (with country deviations)
EN 60825-1 +A1+A2 (1994) Safety of Laser Products—Part 1:
Equipment Classification
EN 60825-2 (2000) Safety of Laser Products—Part 2: Safety
of Optical Fiber Comm. Systems
C-UL to CAN/CSA 22.2 No.60950-1(First Edition)
TUV/GS to EN 60950-1, Amendment A1-A4, A11
CB-IEC60950-1, all country deviations
CE
Electromagnetic Compatibility (EMC)
EN 300 386 V1.3.3 (2005) Telecom Network Equipment—
EMC requirements
FCC Part 15 Class A (2007) USA Radiated Emissions
EN 55022 Class A (2006) European Radiated Emissions
VCCI Class A (2007) Japanese Radiated Emissions
ICES-003 Class A
AS/NZS CISPR 22 Class A
CISPR 22 Class A
Immunity
EN 55024 +A1+A2 (1998) Information Technology Equipment
Immunity Characteristics
EN-61000-3-2 (2006) Power Line Harmonics
EN-61000-3-3 +A1 +A2 +A3 (1995) Power Line Voltage
Fluctuations
EN-61000-4-2 +A1 +A2 (1995) Electrostatic Discharge
EN-61000-4-3 +A1+A2 (2002) Radiated Immunity
EN-61000-4-4 (2004) Electrical Fast Transients
EN-61000-4-5 (2006) Surge
EN-61000-4-6 (2007) Immunity to Conducted Disturbances
EN-61000-4-11 (2004) Voltage Dips and Sags
*Roadmap