User Manual
OK/FAIL LED, one bicolor:
•
Green—MIC is functioning normally.
•
Yellow—MIC has failed.
One tricolor per port:
•
Off—Not enabled.
•
Green—Online with no alarms or failures.
•
Yellow—Online with alarms for remote failures.
•
Red—Active with a local alarm; router has detected a failure.
LEDs
•
Structure-agnostic alarms for T1 and E1 interface:
•
Alarm indication signal (AIS)
•
Loss of signal (LOS)
•
Structure-aware alarms for T1 and E1 interface:
•
Loss of signal (LOS)
•
Alarm indication signal (AIS)
•
Loss of frame (LOF)
•
Remote alarm indication signal (RAIS)
•
Structure-agnostic error detection for T1 and E1 interface:
•
Errored seconds (ES)
•
Line code violation (LCV)
•
Line errored seconds (LES)
•
Severely errored seconds (SES)
•
Unavailable seconds (UAS)
•
Loss of signal seconds (LOSS)
•
Structure-aware error detection for T1 and E1 interface:
•
Severely errored frame (SEF)
•
Block error event (BEE)
•
Line code violation (LCV)
•
Path code violation (PCV)
•
Line errored seconds (LES)
•
Errored seconds (ES)
•
Severely errored seconds (SES)
•
Severely errored frame seconds (SEFS)
•
Bursty errored seconds (BES)
•
Unavailable seconds (UAS)
•
Loss of signal seconds (LOSS)
•
Loss of framing seconds (LOFS)
•
Far-end block error (FEBE) (E1 only)
•
CRC errors (E1 only)
Alarms, errors, and
events
149Copyright © 2013, Juniper Networks, Inc.
Channelized E1/T1 Circuit Emulation MIC