Datasheet
7
Specifications
T640 T1600* T4000 TX Matrix
TX Matrix
Plus
Dimensions and Power
Physical dimensions
(W x H x D)
17.43 x 37.45 x 31 in
(44.27 x 95.12 x
78.74 cm)
17.43 x 37.45 x 31 in
(44.27 x 95.12 x
78.74 cm)
17.43 x 37.45 x 31 in
(44.27 x 95.12 x
78.74 cm)
17.43 x 44.5 x 30 in
(44.27x 113 x 76.2 cm)
21.4 x 52 x 36.2 in
(54.4 x 132 x 91.9 cm)
Maximum weight 565 lb / 256.28 kg 606 lb / 274.88 kg 606 lb/274.88 kg 480 lb / 218 kg 925 lb / 420 Kg
Mounting Front or center
Rack-mount
Front or center
Rack-mount
Front or center
Rack-mount
Front or center
Rack-mount
Front or center
Rack-mount
Power system rating
(agency label)
7,296 W
(152 A @ -48 VDC)
Delta: 28.3 A @
240 VAC maximum
(line-to-line)
Delta: 34 A @
200 VAC minimum
(line-to-line)
Wye: 16.4 A @
415 VAC maximum
(line-to-line)
Wye: 20 A @
346 VAC minimum
(line-to-line)
8,352 W
(174 A @ -48 VDC)
Delta: 28.3 A @
240 VAC maximum
(line-to-line)
Delta: 34 A @
200 VAC minimum
(line-to-line)
Wye: 16.4 A @
415 VAC maximum
(line-to-line)
Wye: 20 A @
346 VAC minimum
(line-to-line)
9,840 W maximum
power @ -48 VDC:
9,840 W and
maximum power per
PEM PWR-T-6-60-DC
as maximum capacity
306 A @ -48 VDC
4,560 W
(95 A @ -48 VDC)
9,200 W
192 A @ -48 VDC
Standalone SIB Yes Ye s Yes N/A N/A
Matrix-enabled SIB Yes Ye s Yes Ye s Yes
Environmental
Temperature 32° to 104° F (0 to 40° C)
Maximum altitude No performance degradation to 10,000 ft (3,048 m)
Relative humidity 5% to 90% non-condensing
Seismic /earthquake Designed to meet Telcordia Zone 4 requirements
Approvals
Safety • CAN/CSA-C22.2 No. 60950-00/UL 60950 – Third Edition, Safety of Information Technology Equipment
• EN 60825-1 Safety of Laser Products – Part 1: Equipment Classification, Requirements and User’s Guide
• EN 60825-2 Safety of Laser Products – Part 2: Safety of Optical Fibre Communications Systems
• EN 60950 Safety of Information Technology Equipment
EMC • AS/NZS 3548 Class A (Australia/New Zealand), BSMI Class A (Taiwan), EN 55022 Class A emissions
(Europe), FCC Class A (USA), VCCI Class A (Japan)
Immunity • EN 61000-3-2 Power Line Harmonics, EN 61000-4-2 ESD, EN 61000-4-3 Radiated Immunity, EN 61000-
4-4 EFT, EN 61000-4-5 Surge, EN 61000-4-6 Low Frequency Common Immunity, EN 61000-4-11 Voltage
Dips and Sags
NEBS All T Series platforms and components are designed to comply with the following NEBS standards:
• GR-63-CORE: NEBS, Physical Protection (including environmental parameters)
• GR-1089-CORE: EMC and Electrical Safety for Network Telecommunications Equipment
• SR-3580 NEBS Criteria Levels (Level 3 Compliance)
ETSI TS-300386-2 Telecommunication Network Equipment Electromagnetic Compatibility
*For T1600, actual energy consumption measured under ATIS/Juniper Energy Consumption Rating (ECR) methodology is 5,640 W. For more information, see Energy Efficiency for Network Equipment
at www.juniper.net, and for the ECR methodology itself, see www.ecrinitiative.org.