Datasheet

Maintaining the M7i Routing Engine
Purpose For optimum performance, verify the condition of the Routing Engine.
Action Check the LEDs on the Routing Engine. The green LED labeled ONLINE lights steadily
when it is functioning normally. For more information about the LEDs, see “M7i Routing
Engine Description” on page 18.
Issue the CLI show chassis routing-engine command to check the status of the Routing
Engines:
user@host> show chassis routing-engine
Routing Engine status:
Temperature 26 degrees C / 78 degrees F
DRAM 256 MB
Memory utilization 27 percent
CPU utilization:
User 0 percent
Background 0 percent
Kernel 4 percent
Interrupt 0 percent
Idle 96 percent
Model RE-5.0
Serial ID 1000392782
Start time 2003-06-11 11:39:32 PDT
Uptime 1 hour, 41 minutes, 51 seconds
Load averages: 1 minute 5 minute 15 minute
0.00 0.03 0.05
For further description of the output from the command, see the Junos OS System Basics
and Services Command Reference.
Related
Documentation
Replacing the M7i Routing Engine on page 101
Routing Engine Interface Cable and Wire Specifications for the M7i Router on page 183
Maintaining the M7i Power Supplies
Purpose For optimum router performance, verify the condition of the power supplies.
Action Check that the green OUTPUT OK LED is lit on the faceplate of both power supplies.
For more information about the LED, see “M7i Power Supply LEDs” on page 25.
Issue the following CLI command to check the status of the power supplies. As shown
in the sample output, the value OK in the Status column indicates that the power supply
is operating normally:
user@host> show chassis environment
Class Item Status Measurement
Power Power Supply 0 OK
Power Supply 1 OK
Temp Intake OK 24 degrees C / 75 degrees F
PICs OK 27 degrees C / 80 degrees F
Power Supplies OK 27 degrees C / 80 degrees F
Copyright © 2012, Juniper Networks, Inc.76
M7i Multiservice Edge Router Hardware Guide