Issue the CLI show chassis cfeb command to check the status of the CFEB (first output
example) or the CFEB-E (second output example):
user@host> show chassis cfeb
CFEB status:
State Online
Intake Temperature 27 degrees C / 80 degrees F
Exhaust Temperature 33 degrees C / 91 degrees F
CPU utilization 3 percent
Interrupt utilization 0 percent
Heap utilization 8 percent
Buffer utilization 21 percent
Total CPU DRAM 128 MB
Internet Processor II Version 1, Foundry IBM, Part number 164
Start time: 2003-06-11 11:41:22 PDT
Uptime: 1 hour, 39 minutes, 31 seconds
user@host> show chassis cfeb
CFEBE status:
State Online
Intake Temperature 27 degrees C / 80 degrees F
Exhaust Temperature 33 degrees C / 91 degrees F
CPU utilization 3 percent
Interrupt utilization 0 percent
Heap utilization 8 percent
Buffer utilization 21 percent
Total CPU DRAM 128 MB
Internet Processor II Version 1, Foundry IBM, Part number 164
Start time: 2003-06-11 11:41:22 PDT
Uptime: 1 hour, 39 minutes, 31 seconds
For further description of the output from the command, see the Junos OS System Basics
and Services Command Reference.
Related
Documentation
Replacing, Upgrading, and Downgrading the M7i CFEB and CFEB-E on page 90
Installing the M7i CFEB and CFEB-E on page 92
Troubleshooting the M7i CFEB and CFEB-E on page 84
Maintaining the M7i FIC and FIC Cables and PICs and PIC Cables
Purpose For optimum performance, verify the condition of the FIC and FIC cables and PICs and
PIC cables.
Action Check the LEDs on the FIC faceplate. The Fast Ethernet and Gigabit Ethernet ports on
the FIC have LEDs that display the status of the ports. For more information, see “M7i
Fixed Interface Card (FIC) Description” on page 15.
Check the LEDs on PIC faceplates. Most PIC faceplates have an LED labeled STATUS.
Some PICs have additional LEDs, often one per port. The meaning of the LED states
differs for various PICs. For more information, see the M7i Multiservice Edge Router PIC
Guide.
Issue the CLI show chassis fpc pic-status command. The following example specifies
an FPC slot number (0), which is optional.