Datasheet

NOTE: After powering off a power supply, wait at least 60 seconds before
turning it back on. After poweringon a power supply, waitatleast 60 seconds
before turning it off.
If the router is completely powered off when you power on the power supply,
the RoutingEngine boots as the powersupplycompletes its startup sequence.
If the Routing Engine finishes booting and you need to power off the router
again, first issue the CLI request system halt command. For more information,
see .
After a power supply is powered on, it can take up to 60 seconds for status
indicators—suchasthe output status LED onthe powersupply, the command
display output, and messages on the LED display on the craft interface—to
indicate that the power supply is functioning normally. Ignore error indicators
that appear during the first 60 seconds.
Related
Documentation
M7i AC Power Supply on page 24
M7i DC Power Supply on page 25
Removing an M7i AC Power Supply on page 112
Troubleshooting the M7i Power System When the LED on One M7i Power Supply Is Off
on page 85
M7i AC Power Supply
An AC-powered router has one or two load-sharing AC power supplies, located at the
bottom rear of the chassis, as shown in Figure 2 on page 6. For information about power
supply redundancy and replaceability, see “M7i Power System Description” on page 23.
Figure 15 on page 24 shows the power supply.
Figure 15: AC Power Supply
Related
Documentation
Table 21 on page 170
M7i Power Supply LEDs on page 25
Installing an M7i AC Power Cord on page 115
Copyright © 2012, Juniper Networks, Inc.24
M7i Multiservice Edge Router Hardware Guide