Datasheet
The following example specifies an FPC slot number (0), which is optional.
user@host> show chassis fpc pic-status 0
Slot 0 Online PIC 0 2x OC-3 ATM, MM PIC 1 2x CT3-NxDS0 PIC 2 2x
OC-3 ATM, MM
For further description of the output from the command, see the Junos OS System Basics
and Services Command Reference.
Related
Documentation
Maintaining the M7i FIC and FIC Cables and PICs and PIC Cables on page 74•
• Replacing an M7i FIC or PIC Cable on page 96
Troubleshooting the M7i Power System
When a power supply is functioning correctly, the green LED labeled OUTPUT OK is lit
steadily.
If any other LED states apply, consult the following topics:
•
Troubleshooting the M7i Power System When the LEDs on All M7i Power Supplies Are
Blinking or Off on page 85
•
Troubleshooting the M7i Power System When the LED on One M7i Power Supply Is
Off on page 85
Troubleshooting the M7i Power System When the LEDs on All M7i Power Supplies Are Blinking
or Off
Problem If the LED is off on all power supply faceplates, either someone has switched off power
to the router or the system temperature has exceeded the acceptable maximum. In the
latter case, the Routing Engine shuts down all power supplies. There is no power to the
router, so no LED is lit, including the alarm LEDs on the craft interface.
Solution Excessive system temperature is almost always caused by excessive environmental
temperature. Correct the environmental temperature before repowering the router.
Related
Documentation
M7i Power System Description on page 23•
• M7i Router Power Requirements on page 167
• Maintaining the M7i Power Supplies on page 76
• Powering On the M7i Router on page 63
Troubleshooting the M7i Power System When the LED on One M7i Power Supply Is Off
Problem The LED on one power supply is off, but the LED on the other supplies indicate that they
are functioning properly.
85Copyright © 2012, Juniper Networks, Inc.
Chapter 14: Troubleshooting M7i Hardware Components