Table 13: Chassis Alarm Messages (continued)
Alarm
SeverityRemedyAlarm Condition
Chassis
Component
Yellow
Check room
temperature.
Check air flow.
Check fan tray.
The chassis temperature has
exceeded 55° C and the fans have
been turned on to full speed and one
or more fans have failed.
Temperature
Yellow
Check room
temperature.
Check air flow.
Check fan tray.
The chassis temperature has
exceeded 65° C and the fans have
been turned on to full speed.
Red
Check room
temperature.
Check air flow.
Check fan tray.
The chassis temperature has
exceeded 65° C and a fan has failed.
If this condition persists for more than
4 minutes, the router shuts down.
Red
Check room
temperature.
Check air flow.
Check fan tray.
The chassis temperature has
exceeded 75° C. If this condition
persists for more than 4 minutes, the
router shuts down.
RedContact technical
support. See
“Contacting Customer
Support” on page 195
for more information.
The temperature sensor has failed.
Table 14: SONET/SDH Interface Alarm Messages
CLI Message
interface-name so-x/x/x - SONET bit error rate defect
interface-name so-x/x/x - SONET bit error rate fault
interface-name so-x/x/x - SONET line AIS
interface-name so-x/x/x - SONET line remote defect indicator
interface-name so-x/x/x - SONET loss of frame
interface-name so-x/x/x - SONET loss of light
interface-name so-x/x/x - SONET loss of pointer
interface-name so-x/x/x - SONET loss of signal
interface-name so-x/x/x - SONET path AIS
83Copyright © 2012, Juniper Networks, Inc.
Chapter 14: Troubleshooting M7i Hardware Components